Continuous Glucose Monitoring: Review of an Innovation in Diabetes Management.

Zainab Mian1, Kathie L Hermayer2, Alicia Jenkins3.   

Abstract

Most continuous glucose monitors (CGM) provide interstitial fluid glucose trends, which reflect blood glucose trends with alarms and alerts to prevent hypoglycemia and provide better glycemic control. CGM used in conjunction with insulin pumps has changed the management of patients with insulin-dependent diabetes, mainly type 1 diabetes. CGM technology prevents the need for frequent blood glucose testing, which is often cumbersome for patients, providing them with a better alternative. CGM technology is underprescribed and therefore advantage should be taken of this technology to provide better hemoglobin A1c (HbA1c) control and decrease incidence of diabetic complications. CGM is particularly useful in patients with hypoglycemia unawareness and nocturnal hypoglycemia. CGM is currently not approved in pregnant patients, in critically ill patients and patients on dialysis. Research suggests that the benefits certainly outweigh the limitations of this technology. This review article focuses on the technical and clinical use of continuous glucose monitoring and sensor-integrated pump technology. Crown
Copyright © 2019. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Continuous glucose monitoring; Fingerstick blood glucose testing; Hyperglycemia; Hypoglycemia; Sensor integrated pump technology

Mesh:

Substances:

Year:  2019        PMID: 31402042     DOI: 10.1016/j.amjms.2019.07.003

Source DB:  PubMed          Journal:  Am J Med Sci        ISSN: 0002-9629            Impact factor:   2.378


  11 in total

1.  Sharing patient-generated data with healthcare providers: findings from a 2019 national survey.

Authors:  Kea Turner; Ara Jo; Grace Wei; Amir Alishahi Tabriz; Alecia Clary; Heather S L Jim
Journal:  J Am Med Inform Assoc       Date:  2021-02-15       Impact factor: 4.497

Review 2.  Artificial intelligence perspective in the future of endocrine diseases.

Authors:  Mandana Hasanzad; Bagher Larijani; Hamid Reza Aghaei Meybodi; Negar Sarhangi
Journal:  J Diabetes Metab Disord       Date:  2022-01-11

3.  The diabetes quality of life brief clinical inventory in combination with the management strategies in type 1 diabetes mellitus with or without the use of insulin pump.

Authors:  Emmanouil S Benioudakis; Evangelos D Georgiou; Eirini D Barouxi; Athanasios M Armagos; Vaia Koutsoumani; Faidra Anastasiou-Veneti; Eleni Koutsoumani; Maria Brokalaki
Journal:  Diabetol Int       Date:  2020-11-16

Review 4.  Advanced Diabetes Management Using Artificial Intelligence and Continuous Glucose Monitoring Sensors.

Authors:  Martina Vettoretti; Giacomo Cappon; Andrea Facchinetti; Giovanni Sparacino
Journal:  Sensors (Basel)       Date:  2020-07-10       Impact factor: 3.576

5.  Impacts of glycemic variability on the relationship between glucose management indicator from iPro2 and laboratory hemoglobin A1c in adult patients with type 1 diabetes mellitus.

Authors:  Hongxia Liu; Daizhi Yang; Hongrong Deng; Wen Xu; Jing Lv; Yongwen Zhou; Sihui Luo; Xueying Zheng; Hua Liang; Bin Yao; Liling Qiu; Funeng Wang; Fang Liu; Jinhua Yan; Jianping Weng
Journal:  Ther Adv Endocrinol Metab       Date:  2020-06-08       Impact factor: 3.565

6.  Oscillatory pattern of glycemic control in patients with diabetes mellitus.

Authors:  Manuel Vasquez-Muñoz; Alexis Arce-Alvarez; Magdalena von Igel; Carlos Veliz; Gonzalo Ruiz-Esquide; Rodrigo Ramirez-Campillo; Cristian Alvarez; Robinson Ramirez-Velez; Fernando A Crespo; Mikel Izquierdo; Rodrigo Del Rio; David C Andrade
Journal:  Sci Rep       Date:  2021-03-11       Impact factor: 4.379

7.  Cost Analysis of FreeStyle Libre® 2 System in Type 2 Diabetes Mellitus Population.

Authors:  Itziar Oyagüez; Fernando Gómez-Peralta; Sara Artola; Francisco J Carrasco; Juana Carretero-Gómez; Javier García-Soidan; Ricardo Gómez-Huelgas; Juan F Merino-Torres; Antonio Pérez
Journal:  Diabetes Ther       Date:  2021-05-04       Impact factor: 2.945

8.  A "Slide Rule" to Adjust Insulin Dose Using Trend Arrows in Adults with Type 1 Diabetes: Test in Silico and in Real Life.

Authors:  Daniela Bruttomesso; Federico Boscari; Giuseppe Lepore; Giulia Noaro; Giacomo Cappon; Angela Girelli; Lutgarda Bozzetto; Andrea Tumminia; Giorgio Grassi; Giovanni Sparacino; Luigi Laviola; Andrea Facchinetti
Journal:  Diabetes Ther       Date:  2021-03-16       Impact factor: 2.945

Review 9.  Molecular Mechanisms of Glucose Fluctuations on Diabetic Complications.

Authors:  Zhen-Ye Zhang; Ling-Feng Miao; Ling-Ling Qian; Ning Wang; Miao-Miao Qi; Yu-Min Zhang; Shi-Peng Dang; Ying Wu; Ru-Xing Wang
Journal:  Front Endocrinol (Lausanne)       Date:  2019-09-18       Impact factor: 5.555

Review 10.  Screening Methods for Diagnosing Cystic Fibrosis-Related Diabetes: A Network Meta-Analysis of Diagnostic Accuracy Studies.

Authors:  Vera Dóra Izsák; Alexandra Soós; Zsolt Szakács; Péter Hegyi; Márk Félix Juhász; Orsolya Varannai; Ágnes Rita Martonosi; Mária Földi; Alexandra Kozma; Zsolt Vajda; James Am Shaw; Andrea Párniczky
Journal:  Biomolecules       Date:  2021-03-31