Literature DB >> 31400649

Assessment of the neutron radiation field with activation foils and intermittent irradiations around a PETtrace biomedical cyclotron.

J A Benavente-Castillo1, M A S Lacerda2, A V Ferreira2, H M Dalle2, T A Da Silva2.   

Abstract

This work aimed at assessing the neutron radiation field with activation foils around of the PETtrace biomedical cyclotron. Activation foils of gold, gold covered with cadmium, indium and nickel was used to evaluate the thermal, epithermal and fast neutron contributions, respectively. The irradiations of the activation foils were performed using the intermittent irradiation method to conciliate the measurements with the routine 18F production. The evaluated points showed the contributions of the thermal, epithermal and fast neutrons due to interaction with the vault room, cyclotron accelerator and main cyclotron components.
Copyright © 2019 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Activation foils; Intermittent irradiation; Neutron activation analysis; PET cyclotron

Mesh:

Year:  2019        PMID: 31400649     DOI: 10.1016/j.apradiso.2019.108823

Source DB:  PubMed          Journal:  Appl Radiat Isot        ISSN: 0969-8043            Impact factor:   1.513


  1 in total

1.  A novel experimental approach to characterize neutron fields at high- and low-energy particle accelerators.

Authors:  Saverio Braccini; Pierluigi Casolaro; Gaia Dellepiane; Isidre Mateu; Lorenzo Mercolli; Andrea Pola; Dario Rastelli; Paola Scampoli
Journal:  Sci Rep       Date:  2022-10-07       Impact factor: 4.996

  1 in total