Literature DB >> 3139355

Improved detection of Mycobacterium avium complex with the Bactec radiometric system.

S E Hoffner1.   

Abstract

A reconsideration of the laboratory methods used for primary isolation of mycobacteria other than Mycobacterium tuberculosis is needed due to the increasingly recognized importance of such mycobacterial infections in immunocompromised patients. One example of this is the severe opportunistic infections caused by Mycobacterium avium complex among AIDS patients. In this study, the Bactec radiometric system was compared to conventional culture on solid medium for the detection of M. avium complex in 3,612 selected clinical specimens, mainly of extrapulmonary origin. Of a total number of 63 M. avium complex isolates, the Bactec system detected 58 (92%), compared to 37 (59%) for conventional culture. A much more rapid detection was attained with radiometric technique than with conventional culture. The mean detection time for the cultures positive with both methods was 7.1 and 28.3 days, respectively. The Bactec radiometric system achieves a rapid and significantly more sensitive detection and seems to be an excellent complement to conventional culture in the laboratory diagnosis of infections with the M. avium complex.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3139355     DOI: 10.1016/0732-8893(88)90121-6

Source DB:  PubMed          Journal:  Diagn Microbiol Infect Dis        ISSN: 0732-8893            Impact factor:   2.803


  8 in total

1.  Specific detection of Mycobacterium tuberculosis complex strains by polymerase chain reaction.

Authors:  P W Hermans; A R Schuitema; D Van Soolingen; C P Verstynen; E M Bik; J E Thole; A H Kolk; J D van Embden
Journal:  J Clin Microbiol       Date:  1990-06       Impact factor: 5.948

2.  Susceptibility of mycobacteria to fusidic acid.

Authors:  S E Hoffner; B Olsson-Liljequist; K J Rydgård; S B Svenson; G Källenius
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1990-04       Impact factor: 3.267

3.  Comparison of fluorescent BACTEC 9000 MB system, Septi-Chek AFB system, and Lowenstein-Jensen medium for detection of mycobacteria.

Authors:  A J van Griethuysen; A R Jansz; A G Buiting
Journal:  J Clin Microbiol       Date:  1996-10       Impact factor: 5.948

4.  Serovars of Mycobacterium avium complex isolated from patients in Sweden.

Authors:  S E Hoffner; G Källenius; B Petrini; P J Brennan; A Y Tsang
Journal:  J Clin Microbiol       Date:  1990-06       Impact factor: 5.948

5.  Controversies in the management of HIV-related illnesses.

Authors:  M Cooke; H Libman; M D Smith; T G Cooney; H Hollander; H J Makadon; P A Volberding
Journal:  J Gen Intern Med       Date:  1991 Jan-Feb       Impact factor: 5.128

6.  Evaluation of the MB/BacT system and comparison to the BACTEC 460 system and solid media for isolation of mycobacteria from clinical specimens.

Authors:  P Rohner; B Ninet; C Metral; S Emler; R Auckenthaler
Journal:  J Clin Microbiol       Date:  1997-12       Impact factor: 5.948

Review 7.  The Mycobacterium avium complex.

Authors:  C B Inderlied; C A Kemper; L E Bermudez
Journal:  Clin Microbiol Rev       Date:  1993-07       Impact factor: 26.132

8.  Mycobacterium malmoense: an easily missed pathogen.

Authors:  S E Hoffner; B Henriques; B Petrini; G Källenius
Journal:  J Clin Microbiol       Date:  1991-11       Impact factor: 5.948

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.