Literature DB >> 31384983

Electrochemical aptasensor for the detection of HER2 in human serum to assist in the diagnosis of early stage breast cancer.

Giselda Bezerra1, Carolina Córdula2, Danielly Campos2, Gustavo Nascimento2, Natália Oliveira2, Maria Aparecida Seabra2, Valeria Visani2, Sampaio Lucas2, Iasmim Lopes2, Joana Santos2, Francisco Xavier2, Maria Amélia Borba2, Danyelly Martins2, José Lima-Filho2.   

Abstract

Human epidermal growth factor receptor-2 (HER2) is an important biomarker in the diagnosis and prognosis of breast cancer. This work aimed to develop an aptasensor to detect HER2 in human serum. HER2 aptamer was immobilized by electrostatic adsorption on the surface of a homemade screen-printed electrode modified with poly-L-lysine. Measurements were made by differential pulse voltammetry using methylene blue as a redox indicator. A calibration curve was constructed (R2 = 0.997) using different concentrations of HER2 protein (10-60 ng/mL) in PBS buffer (pH 7.4), with a detection limit of 3.0 ng/mL. The aptasensor showed good reproducibility with relative standard deviations (RSDs) of 3% and remained stable for 3 days with an RSD around 2%. When the tests were performed with serum from a healthy woman, a peak of 6.72 μA was found without the addition of the protein. When we tested the serum of a woman with HER2+ breast cancer, we obtained a signal of 2.65 μA; the same pattern was found when adding to protein in serum control, i.e., the higher the concentration of protein, the lower the signal. The aptasensor was characterized by scanning electron microscopy and isothermal titration calorimetry (ITC), showing excellent interaction between aptamer and target protein. The results revealed a promising and sensitive tool capable of detecting HER2 protein in human serum with albumin depletion, aiding in the molecular diagnosis of breast cancer. Graphical abstract.

Entities:  

Keywords:  Aptamer; Aptasensor; Breast cancer; Diagnosis; HER2; Screen-printed electrode

Mesh:

Substances:

Year:  2019        PMID: 31384983     DOI: 10.1007/s00216-019-02040-5

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  4 in total

Review 1.  From Small Molecules Toward Whole Cells Detection: Application of Electrochemical Aptasensors in Modern Medical Diagnostics.

Authors:  Robert Ziółkowski; Marta Jarczewska; Łukasz Górski; Elżbieta Malinowska
Journal:  Sensors (Basel)       Date:  2021-01-21       Impact factor: 3.576

2.  Nanodiamond conjugated SARS-CoV-2 spike protein: electrochemical impedance immunosensing on a gold microelectrode.

Authors:  Santheraleka Ramanathan; Subash C B Gopinath; Zool Hilmi Ismail; Sreeramanan Subramaniam
Journal:  Mikrochim Acta       Date:  2022-05-20       Impact factor: 6.408

Review 3.  Recent advances in nanomaterials-based electrochemical immunosensors and aptasensors for HER2 assessment in breast cancer.

Authors:  Rajesh Ahirwar
Journal:  Mikrochim Acta       Date:  2021-09-02       Impact factor: 5.833

4.  Aptasensing nucleocapsid protein on nanodiamond assembled gold interdigitated electrodes for impedimetric SARS-CoV-2 infectious disease assessment.

Authors:  Santheraleka Ramanathan; Subash C B Gopinath; Zool Hilmi Ismail; M K Md Arshad; Prabakaran Poopalan
Journal:  Biosens Bioelectron       Date:  2021-10-27       Impact factor: 10.618

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.