Literature DB >> 31383356

Enantiomeric separation of ivabradine by cyclodextrin-electrokinetic chromatography. Effect of amino acid chiral ionic liquids.

Natalia Casado1, Antonio Salgado2, María Castro-Puyana3, María Ángeles García3, María Luisa Marina4.   

Abstract

A chiral methodology was developed for the first time to ensure the quality control of ivabradine, a novel anti-ischemic and heart rate lowering drug commercialized as a pure enantiomer. With this aim, electrokinetic chromatography (EKC) was employed and the enantiomeric separation of ivabradine was investigated using different anionic and neutral cyclodextrins (CDs) and amino acid-based chiral ionic liquids (CILs) as sole chiral selectors. Baseline separation was only achieved with sulfated CDs, and the best enantiomeric resolution was obtained with sulfated-γ-CD. Under the optimized conditions, ivabradine enantiomers were separated in 6 min with a resolution of 2.7. Nuclear magnetic resonance experiments showed a 1:1 stoichiometry for the enantiomer-CD complexes and apparent and averaged equilibrium constants were determined. The combined use of sulfated-γ-CD and different CILs as dual separation systems was investigated, resulting in a significant increase in the resolution. The use of 5 mM tetrabutylammonium-aspartic acid ([TBA][L-Asp]) in 50 mM formate buffer (pH 2.0) containing 4 mM sulfated-γ-CD were considered the best conditions in terms of resolution and migration times for ivabradine enantiomers. Nevertheless, as no inversion of the enantiomer migration order was observed when combining CILs and sulfated-γ-CD and a good enantiomeric resolution and efficiency were obtained using just sulfated-γ-CD as the sole chiral selector, the analytical characteristics of this method were evaluated, showing good recovery (98% and 103% for S- and R-ivabradine, respectively) and precision values (RSD < 5% for instrumental repeatability, < 6% for method repeatability and < 7% for intermediate precision). The limits of detection (LODs) were 0.22 and 0.28 μg mL-1 for S- and R-ivabradine, respectively, and the method enabled to detect a 0.1% of the enantiomeric impurity, allowing to accomplish the requirements of the International Conference on Harmonisation (ICH) guidelines. Finally, the method was applied to the analysis of a pharmaceutical formulation of ivabradine. The content of R-ivabradine was below the LOD and the amount of S-ivabradine was in agreement to the labeled content.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Capillary electrophoresis; Chiral ionic liquids; Chromatography; Cyclodextrins; Electrokinetic; Enantioseparation; Ivabradine

Year:  2019        PMID: 31383356     DOI: 10.1016/j.chroma.2019.460407

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  3 in total

Review 1.  Challenging Bioanalyses with Capillary Electrophoresis.

Authors:  Courtney J Kristoff; Lloyd Bwanali; Lindsay M Veltri; Gayatri P Gautam; Patrick K Rutto; Ebenezer O Newton; Lisa A Holland
Journal:  Anal Chem       Date:  2019-12-02       Impact factor: 6.986

Review 2.  The Influence of Ionic Liquids on the Effectiveness of Analytical Methods Used in the Monitoring of Human and Veterinary Pharmaceuticals in Biological and Environmental Samples-Trends and Perspectives.

Authors:  Natalia Treder; Tomasz Bączek; Katarzyna Wychodnik; Justyna Rogowska; Lidia Wolska; Alina Plenis
Journal:  Molecules       Date:  2020-01-10       Impact factor: 4.411

Review 3.  Chiral Capillary Electrokinetic Chromatography: Principle and Applications, Detection and Identification, Design of Experiment, and Exploration of Chiral Recognition Using Molecular Modeling.

Authors:  Sami El Deeb; Camilla Fonseca Silva; Clebio Soares Nascimento Junior; Rasha Sayed Hanafi; Keyller Bastos Borges
Journal:  Molecules       Date:  2021-05-11       Impact factor: 4.411