| Literature DB >> 31382925 |
Syunsuke Araki1,2, Atsushi Miki3,4, Katsutoshi Goto1, Tsutomu Yamashita1,5, Tsuyoshi Yoneda1,5, Kazuko Haruishi1,5, Yoshiaki Ieki1, Junichi Kiryu1, Goro Maehara6, Kiyoshi Yaoeda7.
Abstract
BACKGROUND: To investigate the area of foveal avascular zone (FAZ) and macular vessel density (VD) after correction for magnification error in unilateral amblyopia using optical coherence tomography angiography (OCTA).Entities:
Keywords: Amblyopia; Foveal avascular zone; Macular vessel density; Optical coherence tomography angiography; Retina
Mesh:
Year: 2019 PMID: 31382925 PMCID: PMC6683430 DOI: 10.1186/s12886-019-1177-z
Source DB: PubMed Journal: BMC Ophthalmol ISSN: 1471-2415 Impact factor: 2.209
Fig. 1Analysis of optical coherence tomography angiography image. Typical optical coherence tomography angiography images from a patient. a; Superficial capillary plexus (SCP) image. b; Foveal avascular zone (FAZ) area in SCP (region shown in red). c; Binarized OCTA image using ImageJ in SCP. d; Deep capillary plexus (DCP) image. e; FAZ area in DCP (region shown in red). f; Binarized OCTA image using ImageJ in DCP. Vascular densities in SCP and DCP were calculated from binary images in c and f
Demographic and clinical data of patients at OCTA measurements
| Amblyopic eyes | Fellow eyes | ||
|---|---|---|---|
| Age | |||
| Mean ± SD | 9.8 ± 3.4 | NA | |
| Median (range) | 9.0 (7.0 to 12.0) | ||
| Sex (Male: Female) | 4: 11 | NA | |
| Visual acuity (logMAR) | |||
| Mean ± SD | 0.21 ± 0.24 | −0.17 ± 0.03 | < 0.001a |
| Median (range) | 0.15 (− 0.02 to 0.40) | −0.18 (− 0.18 to − 0.18) | |
| Refraction (diopters) | |||
| Mean ± SD | 5.13 ± 2.54 | 1.05 ± 1.96 | < 0.001a |
| Median (range) | 6.00 (4.25 to 6.88) | 1.00 (0.00 to 2.00) | |
| Axial length (mm) | |||
| Mean ± SD | 21.30 ± 1.10 | 22.78 ± 1.36 | < 0.001b |
| Median (range) | 21.11 (20.76 to 21.59) | 23.14 (21.56 to 23.36) | |
N/A: not applicable
Values are shown as mean ± standard deviation and median (interquartile range)
a Wilcoxon signed-rank test; b paired t-test
FAZ, VD, and FMT comparisons between amblyopic and fellow eyes
| Amblyopic eyes | Fellow eyes | ||
|---|---|---|---|
| FAZ (mm2) | |||
| SCP | |||
| Mean ± SD | 0.25 ± 0.07 | 0.30 ± 0.08 | < 0.001b |
| Median (range) | 0.25 (0.23 to 0.29) | 0.32 (0.28 to 0.33) | |
| DCP | |||
| Mean ± SD | 0.31 ± 0.09 | 0.35 ± 0.09 | 0.07b |
| Median (range) | 0.30 (0.26 to 0.34) | 0.33 (0.31 to 0.38) | |
| VD (%) | |||
| SCP | |||
| Mean ± SD | 35.73 ± 0.57 | 35.88 ± 0.67 | 0.43b |
| Median (range) | 35.68 (35.51 to 35.99) | 36.04 (35.56 to 36.36) | |
| DCP | |||
| Mean ± SD | 39.60 ± 0.50 | 39.68 ± 0.50 | 0.55b |
| Median (range) | 39.74 (39.38 to 39.83) | 39.66 (39.32 to 40.04) | |
| FMT (μm) | |||
| Mean ± SD | 227.9 ± 20.5 | 221.2 ± 10.3 | 0.25a |
| Median (range) | 221.4 (213.1 to 236.1) | 221.4 (217.3 to 229.8) | |
DCP: deep capillary plexus, FAZ: foveal avascular zone, FMT: foveal minimum thickness, SCP: superficial capillary plexus, VD: vessel density
Values are shown as mean ± standard deviation and median (interquartile range)
a Wilcoxon signed-rank test; b paired t-test
Previous studies on optical coherence tomography angiography in amblyopia
| FAZ area | VD (3 × 3 mm scan) | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Study | OCTA (algorithm) | Patients with amblyopia | Age (years) | LogMAR of AE | Type of amblyopia | SCP | DCP | SCP | DCP | FMT |
| Lonngi M, 2017 [ | RTVue XR Avanti (SSADA) | 13 | 8.0 ± 4.0 | 0.51 ± 0.17 | Anisometropia, strabismus | No difference | No difference | No difference† | No difference† | No difference |
| Yilmaz I, 2017 [ | RTVue XR Avanti (SSADA) | 15 | 8.2 ± 2.3 | 0.25 ± 0.06 | Strabismus | No difference | No difference | Decreased in AE‡ | Decreased in AE‡ | – |
| Sobral I, 2018 [ | RTVue XR Avanti (SSADA) | 26 | 9.2 ± 2.8 | 0.18 ± 0.21 | Anisometropia, strabismus | No difference | Increased in AE‡ | Decreased in AE | No difference | No difference |
| Demirayak B, 2019 [ | RTVue XR Avanti (SSADA) | 17 | 8.6 ± 2.5 | 0.32 ± 0.06 | Anisometropia, strabismus | No difference | – | No difference | No difference | No difference |
| Our study | NIDEK RS-3000 Advance (CODAA) | 15 | 9.8 ± 3.4 | 0.21 ± 0.24 | Anisometropia, mixed | Decreased in AE | No difference | No difference§ | No difference§ | No difference |
AE: amblyopic eyes, CODAA: complex OCT-signal difference analysis angiography, DCP: deep capillary plexus, FAZ: foveal avascular zone, FMT: foveal minimum thickness, LogMAR: logarithm of the minimum angle of resolution, OCTA: optical coherence tomography angiography, SCP: superficial capillary plexus, SSADA: split-spectrum amplitude-decorrelation algorithm, VD: vessel density
† VD in a 6 × 6-mm area is decreased in amblyopic eyes. ‡ No significant difference is evident between amblyopic and fellow eyes, but a significant difference is present between amblyopic and normal control eyes. § The analysis region of the OCTA image was 2.3 × 2.3-mm after magnification correction. Values are shown as mean ± standard deviation