Literature DB >> 31381980

Fast fluorometric enumeration of E. coli using passive chip.

Esin Nagihan Kasap1, Üzeyir Doğan1, Ferah Çoğun2, Ender Yıldırım2, İsmail Hakkı Boyacı3, Demet Çetin4, Zekiye Suludere5, Uğur Tamer6, Nusret Ertaş7.   

Abstract

In this report, a passive microfluidic chip design was developed for fast and sensitive fluorometric determination of Escherichia coli (E. coli) based on sandwich immunoassay. Initially, magnetic nanoparticles (MNPs) and chitosan modified mercaptopropionic acid capped cadmium telluride (CdTe) quantum dots (QDs) were functionalized with E.coli specific antibody to form a sandwich immunoassay with the E. coli. The magnetic separation and preconcentration of the E.coli from the sample solution was performed in the vial. Conjugation of QDs to the magnetically captured E. coli and washing were performed using a passive type of microchip. The microfluidic chip consists of four microchambers connected to each other by microchannels which act as capillary valves. Signal measurement was performed at the last chamber by using a hand-held spectrofluorometer equipped with a fiber optic reflection probe. The selectivity of the method was tested with Enterobacter aerogenes (E. aerogenes) and Salmonella enteritidis (S. enteritidis), it was observed that these bacteria have no interference effect on E.coli determination. The calibration curve was found to be linear in the range of 101-105 cfu/mL with a correlation coefficient higher than 0.99. The limit of detection was calculated as 5 cfu/mL. The method was successfully applied to spiked tap and lake water samples. The results suggest that the developed method is applicable for on-site E. coli detection and offers several advantages such as large dynamic range, high sensitivity, high selectivity and short analysis time.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  E. coli; Fluorescence; Immunomagnetic separation; Microfluidic chip; Sandwich immunoassay

Year:  2019        PMID: 31381980     DOI: 10.1016/j.mimet.2019.105680

Source DB:  PubMed          Journal:  J Microbiol Methods        ISSN: 0167-7012            Impact factor:   2.363


  1 in total

1.  Microfluidics for the rapid detection of Escherichia coli O157:H7 using antibody-coated microspheres.

Authors:  Bo Song; Jiayuan Yu; Yan Sun; Qiao Wang; Shengnan Xu; Yichen Jia; Shuying Lin; Yueying Zhang; Chen Wang; Yingbo Zhang; Xiaojie Zhang
Journal:  Bioengineered       Date:  2021-12       Impact factor: 3.269

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.