Literature DB >> 31380749

Dynamic In Vivo X-ray Fluorescence Imaging of Gold in Living Mice Exposed to Gold Nanoparticles.

Seongmoon Jung, Taeyun Kim, Wooseung Lee, Hyejin Kim, Hyun Suk Kim, Hyung-Jun Im, Sung-Joon Ye.   

Abstract

Dynamic in vivo biodistribution of gold nanoparticles (GNPs) in living mice was first successfully acquired by a pinhole X-ray fluorescence (XRF) imaging system using polychromatic X-rays. The system consisted of fan-beam X-rays to stimulate GNPs and a 2D cadmium zinc telluride (CZT) gamma camera to collect K-shell XRF photons emitted from the GNPs. 2D XRF images of kidney slices of three Balb/C mice were obtained within 2 minutes of irradiation per slice. 40 mg of GNPs suspended in a 0.2 mL phosphate-buffered saline was injected into the mice via a tail vein. The mice were scanned over a 60 min period after the injection of GNPs in order to acquire a dynamic biodistribution of GNPs. The concentrations of GNPs measured by the CZT gamma camera were then validated by inductively coupled plasma atomic emission spectroscopy and ex vivo L-shell XRF measurements using a silicon drift detector. The GNP concentrations in the right-side kidneys were 1.58% by weight (wt%) at T =0 min and 0.77 wt% at T=60 min after the injection. This investigation showed a dramatically reduced scan time and imaging dose. Hence, we conclude that dynamic in vivo XRF imaging of GNPs is technically feasible in a benchtop system. The developed pinhole XRF imaging system can be a potential molecular imaging modality for metal nanoparticles to emerge as a radiosensitizer and a drug-delivery agent.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 31380749     DOI: 10.1109/TMI.2019.2932014

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  4 in total

1.  Characterization of a Pixelated Cadmium Telluride Detector System Using a Polychromatic X-Ray Source and Gold Nanoparticle-Loaded Phantoms for Benchtop X-Ray Fluorescence Imaging.

Authors:  Sandun Jayarathna; Md Foiez Ahmed; Liam O'Ryan; Hem Moktan; Yonggang Cui; Sang Hyun Cho
Journal:  IEEE Access       Date:  2021-03-29       Impact factor: 3.367

2.  Bias-voltage dependent operational characteristics of a fully spectroscopic pixelated cadmium telluride detector system within an experimental benchtop x-ray fluorescence imaging setup.

Authors:  Hem Moktan; Raj Kumar Panta; Sang Hyun Cho
Journal:  Biomed Phys Eng Express       Date:  2021-12-07

3.  In-situ x-ray fluorescence imaging of the endogenous iodine distribution in murine thyroids.

Authors:  Christian Körnig; Theresa Staufer; Oliver Schmutzler; Tanja Bedke; Andres Machicote; Beibei Liu; Yang Liu; Elisabetta Gargioni; Neus Feliu; Wolfgang J Parak; Samuel Huber; Florian Grüner
Journal:  Sci Rep       Date:  2022-02-21       Impact factor: 4.996

4.  Enabling Coarse X-ray Fluorescence Imaging Scans with Enlarged Synchrotron Beam by Means of Mosaic Crystal Defocusing Optics.

Authors:  Jonas Baumann; Christian Körnig; Theresa Staufer; Christopher Schlesiger; Oliver Schmutzler; Florian Grüner; Wolfgang Malzer; Birgit Kanngießer
Journal:  Int J Mol Sci       Date:  2022-04-23       Impact factor: 5.923

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.