Literature DB >> 31379259

OPTY-LINE remote-controlled adjustable intramedullary device implantation in open-wedge high tibial osteotomy: A prospective proof-of-concept pilot and comparison with Tomofix fixed-plate device method.

Leon Jonker1, Farshid Fallahi2, Jayadeep J Saraswathy2, John Edge2, Matt Dawson2.   

Abstract

PURPOSE: The objective was to evaluate the clinical and patient-related short- to medium-term performance of the OPTY-LINE nail device for high tibial osteotomy (HTO), comparing a case series of the said device to the established Tomofix fixed-plate device. PATIENTS AND METHODS: Males with symptomatic medial compartmental osteoarthritis and no serious (co-morbid) knee pathology were followed up, five Tomofix and six OPTY-LINE patients. Patients underwent computed tomography assessment and completed Knee Injury and Osteoarthritis Outcome score (KOOS) and osteotomy surgery patient satisfaction questionnaires, 3 and 6 months post-surgery. A radiologist impression score and a quantitative digital bone density analysis were performed by two independent radiologists. Mann-Whitney U test was applied for inferential statistical tests.
RESULTS: At 6 months post-surgery, for Tomofix, the median radiologists' healing impression score was 'progressive healing' versus 'union virtually complete' for the OPTY-LINE nail; bone healing quotient was 1.30 (standard deviation (SD) 1.74) versus 1.78 (SD 1.58), p = 0.18. The post-operative absolute surgical accuracy was a mean 12 (7.5) for Tomofix versus 4.1 (2.3) for OPTY-LINE, p = 0.052. At baseline, however, Tomofix patients had more knee symptoms, as determined by KOOS symptom sub-score, when compared to the OPTY-LINE cohort (p = 0.009).
CONCLUSION: This initial, non-randomized, comparative evaluation of the OPTY-LINE device for HTO has produced similar outcomes to patients treated with the established Tomofix device. In particular, the rate of post-surgical bone regeneration and surgical accuracy achieved with the OPTY-LINE device are encouraging. Large-scale randomized controlled studies with longer follow-up are indicated to further evaluate the clinical and patient-related outcome performance for OPTY-LINE.

Entities:  

Keywords:  KOOS score; bone healing; bone regeneration; computerized tomography; high tibial osteotomy; intramedullary device

Mesh:

Year:  2019        PMID: 31379259     DOI: 10.1177/2309499019864721

Source DB:  PubMed          Journal:  J Orthop Surg (Hong Kong)        ISSN: 1022-5536            Impact factor:   1.118


  2 in total

Review 1.  Role of high tibial osteotomy in medial compartment osteoarthritis of the knee: Indications, surgical technique and outcomes.

Authors:  Raghbir S Khakha; Hamid Rahmatullah Bin Abd Razak; Kristian Kley; Ronald van Heerwaarden; Adrian J Wilson
Journal:  J Clin Orthop Trauma       Date:  2021-10-01

2.  Longer Term Outcomes Following High Tibial Osteotomy for Osteoarthritis: A Prospective, Multi-Centre Observational Study Comparing Tomofix and OPTY-LINE Devices.

Authors:  Leon Jonker; Lucy Bell; Maureen Monda; James Murray; Matt Dawson
Journal:  Indian J Orthop       Date:  2021-01-21       Impact factor: 1.251

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.