Literature DB >> 31377281

Optic Nerve Sheath Diameter Ultrasound: Optic Nerve Growth Curve and Its Application to Detect Intracranial Hypertension in Children.

Liviana Fontanel1, Stefano Pensiero2, Luca Ronfani3, Valentina Rosolen3, Egidio Barbi4.   

Abstract

PURPOSE: First, to create an optic nerve growth curve from normal optic nerve sheath diameter (ONSD) values measured by using B-scan ultrasonography in subjects 0-18 years of age. Second, to identify age-appropriate cutoff values of ONSD to be used in the diagnosis of intracranial hypertension (IHT).
DESIGN: Prospective cross-sectional study.
METHODS: B-scan ocular ultrasonography was performed on both eyes of 215 subjects 0-18 years of age, divided into 3 groups: 165 healthy children, 29 children with IHT (all >4 years of age), and 21 children with optic disc drusen (ODD).
RESULTS: There were no statistically significant differences in between the ONSDs of healthy children and those in subjects with ODD. An optic nerve growth curve was created by using ONSDs measured in healthy subjects 0-18 years of age, using the equation: ONSD = ln [33.15] - (-0.18 × ln [children's age]). The curve showed a progressive increase of ONSD up to 10 years of age, and it remained constant until the age of 18. For this reason, 2 different cutoff values were calculated for age groups 4-10 and 11-18. Values were 4.10 mm and 4.4 mm, respectively, with a 100.0% sensitivity and a specificity ranging from 83.9% to 98.8%. A sensitivity of 28.6% was reached for the population of subjects 4-18 years of age with a threshold value of 5 mm, as used in published reports.
CONCLUSIONS: The ONSD continued to enlarge gradually until the age of 10. Therefore, 2 different cutoff values for the age groups 4-10 and 11-18 were calculated, considering the ONSDs of subjects 11-18 years of age overlapping with those of adults. No patients with IHT <4 years old were found. Further studies are needed to evaluate the correct cutoff values for these ages.
Copyright © 2019 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2019        PMID: 31377281     DOI: 10.1016/j.ajo.2019.07.014

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  4 in total

1.  Dynamic Optic Nerve Sheath Diameter (ONSD) guided management of raised intracranial pressure in pediatric acute liver failure.

Authors:  Priti Vijay; Bikrant Bihari Lal; Vikrant Sood; Rajeev Khanna; Yashwant Patidar; Seema Alam
Journal:  Hepatol Int       Date:  2021-02-24       Impact factor: 6.047

2.  Predictive Value of Optic Nerve Sheath Diameter for Diagnosis of Intracranial Hypertension in Children With Severe Brain Injury.

Authors:  Fleur Cour-Andlauer; Aurélie Portefaix; Isabelle Wroblewski; Muriel Rabilloud; Fabienne Bordet; Bérengère Cogniat; Capucine Didier; Robin Pouyau; Frédéric V Valla; Behrouz Kassai-Koupai; Gaëlle Siméon; Tiphanie Ginhoux; Sonia Courtil-Teyssedre; Etienne Javouhey
Journal:  Front Pediatr       Date:  2022-06-06       Impact factor: 3.569

Review 3.  Is Ocular Sonography a Reliable Method for the Assessment of Elevated Intracranial Pressure in Children?

Authors:  Dincer Yildizdas; Nagehan Aslan
Journal:  J Pediatr Intensive Care       Date:  2020-09-07

Review 4.  Optic Nerve Sheath Diameter Ultrasound: A Non-Invasive Approach to Evaluate Increased Intracranial Pressure in Critically Ill Pediatric Patients.

Authors:  Giulia Cannata; Stefano Pezzato; Susanna Esposito; Andrea Moscatelli
Journal:  Diagnostics (Basel)       Date:  2022-03-21
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.