Certification and stability assessment of recombinant human growth hormone as a certified reference material for protein quantification.

Thi Thanh Huong Tran1, Juok Kim2, Nordiana Rosli1, Inkyu Mok1, Kyong Hwa Oh1, Hwashim Lee3, Seon-Pyo Hong4, You-Xun Jin5, Liqing Wu5, Jing Wang5, Yohei Sakaguchi6, Tomoya Kinumi6, Akiko Takatsu6, Sook-Kyung Kim1, Ji-Seon Jeong7.   

Abstract

A certified reference material (CRM) for the quantification of protein, essential to manage quality control and quality assurance in protein-related works, has been developed. Amino acid analysis with conventional acid hydrolysis and isotope dilution HPLC-MS was used to establish an SI-traceable absolute protein quantification method using recombinant human growth hormone (hGH) as a model protein. The certification method was verified by comparative studies between 1) different methods of protein quantification based on microwave-assisted hydrolysis, and 2) different labs as part of the Asian Collaboration on Reference Material project with Japan, China, and Korea. Certification, evaluation of measurement uncertainty, homogeneity testing, and stability testing were carried out, after which the candidate CRM for hGH quantification was successfully certified with excellent agreement within the certified value in the two comparative studies. Although the quantification value of hGH by amino acid analysis showed good robustness in various conditions, results of intact protein analysis showed degradation profiles in temperatures higher than 4 °C. Consequently, storage and dissemination conditions should be set in accordance with stability tests. Based on the results, this method is believed to be suitable for accurate quantification of hGH. Additionally, it can also be used as a guide to preparation of CRM, and instructions for quality management of protein work for other similar proteins.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Certified reference material; Human growth hormone; International comparison; Protein quantification; Stability assessment

Year:  2019        PMID: 31376580     DOI: 10.1016/j.jchromb.2019.121732

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  1 in total

1.  Measurement comparability of insulin assays using conventional immunoassay kits.

Authors:  Nordiana Rosli; Ha-Jeong Kwon; Jinsook Lim; Young Ahn Yoon; Ji-Seon Jeong
Journal:  J Clin Lab Anal       Date:  2022-05-27       Impact factor: 3.124

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.