Literature DB >> 3136239

Cost effectiveness in the detection of renal artery stenosis.

W L England1, C E Grim, M H Weinberger, S D Roberts.   

Abstract

Cost effectivenesses of four tests for diagnosing renal artery stenosis were examined. Sensitivity, specificity, cost per patient, and cost per stenosis found for a variety of diagnostic strategies using these tests were retrospectively evaluated using clinical data from 605 hypertensive patients. Cost effectiveness of a given strategy was found to depend on the sequence in which the tests were performed, but to be relatively independent of the exact cost of the tests. Auscultation for a systolic/diastolic abdominal bruit was the most cost-effective test for beginning a diagnostic strategy and showed a 99.6% specificity for stenosis. When the patient has a systolic bruit only or no bruit, plasma renin activity measurement should guide the clinician's choice of whether to test further with intravenous pyelography or renal arteriography. Diagnosis of renal artery stenosis using these tests is estimated to cost between $2,300 and $6,200 per stenosis found, depending on the prevalence of renal artery stenosis.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3136239     DOI: 10.1007/bf02595792

Source DB:  PubMed          Journal:  J Gen Intern Med        ISSN: 0884-8734            Impact factor:   5.128


  17 in total

1.  What do we gain from the sixth stool guaiac?

Authors:  D Neuhauser; A M Lewicki
Journal:  N Engl J Med       Date:  1975-07-31       Impact factor: 91.245

2.  Measures of clinical efficacy. Cost-effectiveness calculations in the diagnosis and treatment of hypertensive renovascular disease.

Authors:  B J McNeil; P D Varady; B A Burrows; S J Adelstein
Journal:  N Engl J Med       Date:  1975-07-31       Impact factor: 91.245

3.  Hypertension induced by oral contraceptives containing estrogen and gestagen. Effects on plasma renin activity and aldosterone excretion.

Authors:  M H Weinberger; R D Collins; A J Dowdy; G W Nokes; J A Luetscher
Journal:  Ann Intern Med       Date:  1969-11       Impact factor: 25.391

4.  Screening for renovascular hypertension. Is renal digital-subtraction angiography the preferred noninvasive test?

Authors:  R J Havey; F Krumlovsky; F delGreco; H G Martin
Journal:  JAMA       Date:  1985-07-19       Impact factor: 56.272

5.  Improved diagnostic accuracy of renal venous renin ratios with stimulation of renin release.

Authors:  A Melman; J P Donohue; M H Weinberger; C E Grim
Journal:  J Urol       Date:  1977-02       Impact factor: 7.450

6.  Primary aldosteronism: diagnosis and differentiation of subtypes.

Authors:  M H Weinberger
Journal:  Ann Intern Med       Date:  1984-02       Impact factor: 25.391

7.  Maximum Shannon information content of diagnostic medical testing. Including application to multiple non-independent tests.

Authors:  R D Rifkin
Journal:  Med Decis Making       Date:  1985       Impact factor: 2.583

8.  The distinction between cost and charges.

Authors:  S A Finkler
Journal:  Ann Intern Med       Date:  1982-01       Impact factor: 25.391

Review 9.  Optimizing work-up of adult hypertensive patients for renal artery stenosis. Observations about hypertensive urography, digital subtraction arteriography, and patient selection.

Authors:  J R Thornbury; J C Stanley; D G Fryback
Journal:  Radiol Clin North Am       Date:  1984-06       Impact factor: 2.303

10.  Diagnosis of secondary forms of hypertension. A comprehensive protocol.

Authors:  C E Grim; M H Weinberger; J T Higgins; N J Kramer
Journal:  JAMA       Date:  1977-03-28       Impact factor: 56.272

View more
  2 in total

1.  More on cost effectiveness in detecting renal artery stenosis.

Authors:  W D Linn; C D Mulrow; M R Tuley
Journal:  J Gen Intern Med       Date:  1989 Jan-Feb       Impact factor: 5.128

Review 2.  Cost effectiveness of coronary heart disease prevention strategies in adults.

Authors:  A D Brown; A M Garber
Journal:  Pharmacoeconomics       Date:  1998-07       Impact factor: 4.981

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.