Literature DB >> 31360377

Quantitative Analysis of Skin Erythema Due to Laser Hair Removal: A Diffusion Optical Spectroscopy Analysis.

Mozhdeh Babadi1, Ezeddin Mohajerani1, Leila Ataie-Fashtami2, Nasrin Zand3, Afshan Shirkavand1,3.   

Abstract

Introduction: Laser hair removal needs an accurate understanding of tissue structure and chromophores content in order to optimize the selection of laser irradiation parameters. None of the optimized laser therapy might lead to side effects in skin tissue such as severe erythema, burn, scar etc. Therefore, guidance by a noninvasive real-time diagnostic method like optical spectroscopy technique is beneficial. The purpose of this survey is to analysis the skin hemoglobin spectrum quantitatively before and after hair removal laser irradiation to minimize the side effects of the procedure.
Methods: To carry out a spectroscopy study, a halogen-tungsten light source was used in the wavelength region of 400-700 nm on an ocean optic device. The measurements were made on the facial area under identical conditions. Total 19 volunteers for laser hair removal by gentle laser Candela, ranging 14- 49 years old, were included in the study. A total of 18 spectra were taken from each person, 9 spectra before hair removal as a reference and 9 subsequent spectra. Colorimetry was done for all acquired before and after spectrums using Origin software (version 8.6). Then, the erythema index derived for each spectrum. Statistical analysis of correlation and normalization in colorimetry data were done using data analysis by SPSS (version 16).
Results: Spectra analysis, before and after optical reflectance spectrums in laser hair removal procedure, revealed the subpeak derivation, and concentration on special visible wavelength 510- 610 nm. We studied the changes of skin chromophores absorption. The derived erythema index [E] and colorimetry parameters a*, b*, l* were compared and correlated statistically. There was a statistically considerable direct linear correlation between a* and E while inverse linear correlation was observed for l* and E and no correlation for b* and E.
Conclusion: Diffuse reflectance spectroscopy showed its potency as an accurate, noninvasive realtime as complementary method for laser treatment to detect erythema as a complication of the method, in order to optimize the parameters based on the tissue characteristics in various candidates.

Entities:  

Keywords:  Colorimetry; Diffuse reflectance; Erythema; Laser hair removal; Spectrum analysis

Year:  2019        PMID: 31360377      PMCID: PMC6499568          DOI: 10.15171/jlms.2019.16

Source DB:  PubMed          Journal:  J Lasers Med Sci        ISSN: 2008-9783


  2 in total

1.  Characterization of an Enzyme-Catalyzed Crosslinkable Hydrogel as a Wound Dressing in Skin Tissue Engineering.

Authors:  Mohammad Ali Nilforoushzadeh; Amir Behtash Amiri; Behrad Shaghaghi; Alimohammad Alimohammadi; Rahim Ahmadi; Ebrahim Khodaverdi Darian; Mohammadreza Razzaghi; Mostafa Rezaei Tavirani; Sona Zare
Journal:  J Lasers Med Sci       Date:  2021-12-01

2.  Biophysical evaluation of treating adipose tissue-derived stem cells using non-thermal atmospheric pressure plasma.

Authors:  Elham Shojaei; Sona Zare; Afshan Shirkavand; Esmaeil Eslami; Sara Fathollah; Parvin Mansouri
Journal:  Sci Rep       Date:  2022-07-01       Impact factor: 4.996

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.