Literature DB >> 31359888

Fabrication of Flexible Superconducting Wiring with High Current-Carrying Capacity Indium Interconnects.

N S DeNigris1, J A Chervenak1, S R Bandler1, M P Chang2, N P Costen2, M E Eckart1, J Y Ha3, C A Kilbourne1, S J Smith4.   

Abstract

The X-ray integral field unit (X-IFU) is a cryogenic spectrometer for the Advanced Telescope for High ENergy Astrophysics (ATHENA). ATHENA is a planned next-generation space-based X-ray observatory with capabilities that surpass the spectral resolution of prior missions. Proposed device designs contain up to 3840 transition edge sensors, each acting as an individual pixel on the detector, presenting a unique challenge for wiring superconducting leads in the focal plane assembly. In prototypes that require direct wiring, the edges of X-IFU focal plane have hosted aluminum wirebonding pads; however, indium (In) 'bumps' deposited on an interface layer such as molybdenum nitride (MoN) can instead be used as an array of superconducting interconnects. We investigated bumped MoN:In structures with different process cleans and layer thicknesses. Measurements of the resistive transitions showed variation of transition temperature T c as a function of bias and generally differed from the expected bulk T c of In (3.41 K). Observed resistance of the In bump structures at temperatures below the MoN transition (at 8.0 K) also depended on the varied parameters. For our proposed X-IFU geometry (10 μm of In mated to a 1-μm In bump), we measured a minimum T c of 3.14 K at a bias current of 3 mA and a normal resistance of 0.59 mΩ per interconnect. We also investigated the design and fabrication of superconducting niobium (Nb) microstrip atop flexible polyimide. We present a process for integrating In bumps with the flexible Nb leads to enable high-density wiring for the ATHENA X-IFU focal plane.

Entities:  

Keywords:  Indium interconnects; Superconducting flexible wiring; X-IFU

Year:  2018        PMID: 31359888      PMCID: PMC6662641          DOI: 10.1007/s10909-018-2019-8

Source DB:  PubMed          Journal:  J Low Temp Phys        ISSN: 0022-2291            Impact factor:   1.570


  1 in total

1.  Lynx x-ray microcalorimeter.

Authors:  Simon R Bandler; James A Chervenak; Aaron M Datesman; Archana M Devasia; Michael DiPirro; Kazuhiro Sakai; Stephen J Smith; Thomas R Stevenson; Wonsik Yoon; Douglas Bennett; Benjamin Mates; Daniel Swetz; Joel N Ullom; Kent D Irwin; Megan E Eckart; Enectali Figueroa-Feliciano; Dan McCammon; Kevin Ryu; Jeffrey Olson; Ben Zeiger
Journal:  J Astron Telesc Instrum Syst       Date:  2019-05-31       Impact factor: 1.436

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.