Heather Carmichael1, Anthony P D'Andrea2, Matthew Skancke3, Vincent Obias3, Patricia Sylla4. 1. Department of Surgery, University of Colorado, Denver, CO, USA. 2. Division of Colon and Rectal Surgery, Department of Surgery, Icahn School of Medicine at Mount Sinai, 5 East 98th Street, Box 1259, New York, NY, 10029, USA. 3. Department of General Surgery and Colorectal Surgery, George Washington University School of Medicine, Washington, DC, USA. 4. Division of Colon and Rectal Surgery, Department of Surgery, Icahn School of Medicine at Mount Sinai, 5 East 98th Street, Box 1259, New York, NY, 10029, USA. patricia.sylla@mountsinai.org.
Abstract
BACKGROUND: The use of transanal total mesorectal excision (taTME) for treatment of rectal cancer is growing, but anatomic constraints prevent access to the proximal rectum with rigid instruments. The articulated instrumentation of current surgical robots is promising in overcoming these limitations, but the bulky size of current platforms inhibits the proximal reach of dissection. Flexible robotic systems could overcome these constraints while maintaining a stable platform for dissection. The goal of this study was to evaluate feasibility of performing taTME using the semi-robotic Flex® System (Medrobotics Corp., Raynham, MA) in human cadavers. METHODS: taTME was performed by two surgeons in six fresh human cadaveric specimens using the Flex® System, with or without transabdominal laparoscopic assistance. Both mid- and low-rectal lesions were simulated. Metrics including quality of visualization, maintenance of pneumorectum, maneuverability of instruments, effectiveness of pursestring suture placement, and dissection in an anatomically correct plane were evaluated. RESULTS: The semi-robotic endoluminal platform allowed for excellent visualization, insufflation, and dissection during taTME. Adequate pursestring occlusion of the rectum was achieved in all six cases. In cadavers with simulated mid-rectal lesions (N = 4), dissection and anterior peritoneal entry was achieved in all cases, with abdominal assistance utilized in two of four cases. In cadavers with simulated low-rectal lesions (N = 2), dissection was incomplete and aborted due to difficulty maneuvering instruments in close proximity to the rigid transanal port. CONCLUSIONS: Use of the Flex® system for taTME is feasible for mid-rectal dissection. Advantages over the traditional multi-armed robot include longer reach of instruments with the ability to dissect up to 17 cm from the anal verge, as well as tactile feedback. The current design of the flexible platform does not permit safe dissection in the distal rectum, although this constraint may be resolved with future adjustments to the equipment.
BACKGROUND: The use of transanal total mesorectal excision (taTME) for treatment of rectal cancer is growing, but anatomic constraints prevent access to the proximal rectum with rigid instruments. The articulated instrumentation of current surgical robots is promising in overcoming these limitations, but the bulky size of current platforms inhibits the proximal reach of dissection. Flexible robotic systems could overcome these constraints while maintaining a stable platform for dissection. The goal of this study was to evaluate feasibility of performing taTME using the semi-robotic Flex® System (Medrobotics Corp., Raynham, MA) in human cadavers. METHODS: taTME was performed by two surgeons in six fresh human cadaveric specimens using the Flex® System, with or without transabdominal laparoscopic assistance. Both mid- and low-rectal lesions were simulated. Metrics including quality of visualization, maintenance of pneumorectum, maneuverability of instruments, effectiveness of pursestring suture placement, and dissection in an anatomically correct plane were evaluated. RESULTS: The semi-robotic endoluminal platform allowed for excellent visualization, insufflation, and dissection during taTME. Adequate pursestring occlusion of the rectum was achieved in all six cases. In cadavers with simulated mid-rectal lesions (N = 4), dissection and anterior peritoneal entry was achieved in all cases, with abdominal assistance utilized in two of four cases. In cadavers with simulated low-rectal lesions (N = 2), dissection was incomplete and aborted due to difficulty maneuvering instruments in close proximity to the rigid transanal port. CONCLUSIONS: Use of the Flex® system for taTME is feasible for mid-rectal dissection. Advantages over the traditional multi-armed robot include longer reach of instruments with the ability to dissect up to 17 cm from the anal verge, as well as tactile feedback. The current design of the flexible platform does not permit safe dissection in the distal rectum, although this constraint may be resolved with future adjustments to the equipment.
Entities:
Keywords:
Natural orifice transluminal endoscopic surgery (NOTES); Proctectomy; Rectal cancer; Robotic surgery; Robotic transanal total mesorectal excision; Transanal total mesorectal excision (taTME)
Authors: M Remacle; V M N Prasad; G Lawson; L Plisson; V Bachy; S Van der Vorst Journal: Eur Arch Otorhinolaryngol Date: 2015-02-08 Impact factor: 2.503
Authors: Marta Penna; Roel Hompes; Steve Arnold; Greg Wynn; Ralph Austin; Janindra Warusavitarne; Brendan Moran; George B Hanna; Neil J Mortensen; Paris P Tekkis Journal: Ann Surg Date: 2017-07 Impact factor: 12.969
Authors: T W A Koedam; M Veltcamp Helbach; P M van de Ven; Ph M Kruyt; N T van Heek; H J Bonjer; J B Tuynman; C Sietses Journal: Tech Coloproctol Date: 2018-03-22 Impact factor: 3.781
Authors: Martijn Hgm van der Pas; Eva Haglind; Miguel A Cuesta; Alois Fürst; Antonio M Lacy; Wim Cj Hop; Hendrik Jaap Bonjer Journal: Lancet Oncol Date: 2013-02-06 Impact factor: 41.316
Authors: Andrew R L Stevenson; Michael J Solomon; John W Lumley; Peter Hewett; Andrew D Clouston; Val J Gebski; Lucy Davies; Kate Wilson; Wendy Hague; John Simes Journal: JAMA Date: 2015-10-06 Impact factor: 56.272
Authors: D Wilhelm; T Vogel; A Jell; S Brunner; M Kranzfelder; N Wantia; H Feussner; D Ostler; S Koller Journal: Surg Endosc Date: 2020-04-06 Impact factor: 4.584