Literature DB >> 31350048

3-dimensional Ability Assessment in Removing Root Filling Material from Pair-matched Oval-shaped Canals Using Thermal-treated Instruments.

Gustavo De-Deus1, Felipe Gonçalves Belladonna2, Arthur de Siqueira Zuolo2, Daniele Moreira Cavalcante2, Marco Simões Carvalho2, Alessandra Marinho2, Erick Miranda Souza3, Ricardo Tadeu Lopes4, Emmanuel João Nogueira Leal Silva5.   

Abstract

INTRODUCTION: The purpose of this study was to evaluate the ability of the XP-endo Shaper instrument (FKG Dentaire, La Chaux-de-Fonds, Switzerland) during the removal of root fillings from oval-shaped canals. M-Wire Reciproc and Reciproc Blue systems (VDW, Munich, Germany) were used as reference instruments for comparison, and micro-computed technology was used as an analytical tool.
METHODS: Thirty mandibular incisors with oval-shaped canals were matched based on similar anatomic features of the canal (eg, volume, aspect ratio, and 3-dimensional configuration) after scanning procedures. The canals were prepared with M-Wire Reciproc R25 instruments and filled with gutta-percha and AH Plus sealer (Dentsply DeTrey, Konstanz, Germany) using the continuous wave of condensation technique. Then, the sample was allocated into 3 experimental groups (n = 10) according to the retreatment protocol used: M-Wire Reciproc, Reciproc Blue, and XP-endo Shaper. M-Wire Reciproc R25, Reciproc Blue R25, and XP-endo Shaper instruments were used to remove the root fillings. Apical enlargement was performed with M-Wire Reciproc R40, Reciproc Blue R40, and BioRace BR5 (FKG Dentaire) instruments. Each sample was scanned after each endodontic procedure. The volume of remaining root filling material was quantified before and after apical enlargement. The percentage volumes of root filling reduction in relation to the instrumented canals at both time points (before and after apical enlargement) were calculated and considered for statistical analysis. Data were analyzed statistically with a significance level of 5%.
RESULTS: Reciproc Blue presented significantly lower removal of filling material compared with the XP-endo Shaper (Tukey test, P < .05). No difference was detected either between M-Wire Reciproc and Reciproc Blue (Tukey test, P > .05) or M-Wire Reciproc and XP-endo Shaper (Tukey, P > .05). The increase of apical enlargement significantly improved the removal of root fillings from the root canals (P < .05); this effect was similar for all systems (time point × file system, P > .05).
CONCLUSIONS: The XP-endo Shaper instrument showed a higher percentage of root filling removal, but no differences were observed comparing M-Wire Reciproc with the XP-endo Shaper or Reciproc Blue. The increase of apical enlargement improved the removal of root fillings in all groups. None of them was able to render root canals completely free from root fillings.
Copyright © 2019 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Micro–computed tomography; XP-endo Shaper; oval-shaped canals; root canal retreatment; root filling material

Year:  2019        PMID: 31350048     DOI: 10.1016/j.joen.2019.06.003

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  6 in total

1.  Comparison of the efficacy of three different supplementary cleaning protocols in root-filled teeth with a bioceramic sealer after retreatment-a micro-computed tomographic study.

Authors:  Chanakarn Sinsareekul; Sirawut Hiran-Us
Journal:  Clin Oral Investig       Date:  2021-12-02       Impact factor: 3.573

2.  Influence of pecking frequency at working length on the volume of apically extruded debris: A micro-computed tomography analysis.

Authors:  Li-Xiao Wang; Hui Chen; Rui-Tian Lin; Li-Sha Gu
Journal:  J Dent Sci       Date:  2021-12-06       Impact factor: 3.719

3.  Apical transportation using Mtwo or Reciproc retreatment systems in severely curved canals: a micro-computed tomographic study.

Authors:  Isabelle L L Gomes; Flávio R F Alves; Marília F Marceliano-Alves; Stephanie B Silveira; Júlio Cézar N Sousa; José Claudio Provenzano; Lucio Souza Gonçalves
Journal:  Clin Oral Investig       Date:  2022-10-20       Impact factor: 3.606

4.  Micro-tomographic analysis of the root trunk and pre-furcation area of the first mandibular molars.

Authors:  Dyego Jhony Perminio; Diogo Moreira Rodrigues; Katia Costa Vianna; Alessandra Machado; Ricardo Lopes; Eliane Porto Barboza
Journal:  Odontology       Date:  2021-08-13       Impact factor: 2.634

5.  Micro-CT analysis of dentinal microcracks on root canals filled with a bioceramic sealer and retreated with reciprocating instruments.

Authors:  Andressa Almeida; Kaline Romeiro; Marcely Cassimiro; Luciana Gominho; Eugênia Dantas; Silmara Silva; Diana Albuquerque
Journal:  Sci Rep       Date:  2020-09-17       Impact factor: 4.379

6.  Safety and Effectiveness of Additional Apical Preparation using a Rotary Heat-treated Nickel-Titanium file with Larger Diameter and Minimum Taper in Retreatment of Curved Root Canals.

Authors:  Jader Camilo Pinto; Fernanda Ferrari Esteves Torres; Airton Oliveira Santos-Junior; Marco Antonio Hungaro Duarte; Juliane Maria Guerreiro-Tanomaru; Mario Tanomaru-Filho
Journal:  Eur J Dent       Date:  2021-02-23
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.