Literature DB >> 31346784

Evaluation of polymerization shrinkage of bulk-fill resin composites using microcomputed tomography.

Kadriye Aybüke Ersen1, Özge Gürbüz2, Mutlu Özcan3.   

Abstract

OBJECTIVES: This study evaluated the influence of cavity depth on polymerization shrinkage of bulk-fill resin composites with and without adhesive resin.
MATERIALS AND METHODS: Standardized box-shaped cavities (width, 4 mm; length, 5 mm, depth, 2 mm or 4 mm) were made on occlusal surfaces of extracted human third molars (N = 60). The teeth were assigned to 3 groups to receive bulk-fill resin composites (low-viscosity bulk-fill, SDR; high-viscosity bulk-fill; Filtek Bulk-Fill-FB; and TetricEvo Ceram Bulk-Fill-TB) in the prepared cavities with and without adhesive resin (Clearfil S3 Bond). Each specimen (n = 5 per group) was scanned twice using microcomputed tomography (micro-CT): once after application of the resin composite to the cavity prior to polymerisation and once after polymerisation. The shrinkage of volumetric loss (%) was measured using micro-CT. Data were analysed using Kruskal-Wallis and Mann-Whitney U tests (alpha = 0.05).
RESULTS: The material type (p < 0.05), application of adhesive resin (p < 0.05) and cavity depth (p < 0.05) significantly affected the shrinkage values. The interaction terms were also significant (p < 0.05). All the bulk-fill resin composites tested showed significantly less shrinkage when applied in cavities with adhesive resin (0.94-2.55) compared with those without (2.01-3.45) (p < 0.05) and presented significantly more shrinkage after polymerisation (p < 0.05). At a 2-mm cavity depth without (2 mm, 2.28; 4 mm, 2.41) and with adhesive (2 mm, 0.94; 4 mm, 1.67), significantly less shrinkage was observed with FB compared with SDR and TB (p < 0.05). At a 4-mm cavity depth without (3.14) and with adhesive (2.55), SDR showed significantly higher shrinkage compared with FB and TB (p < 0.05).
CONCLUSIONS: The bulk-fill composites tested presented less shrinkage when used in conjunction with adhesive resin application on dentin. Overall, the low-viscosity bulk-fill resin SDR showed more shrinkage compared with high-viscosity resins tested. CLINICAL RELEVANCE: Low- or high-viscosity bulk-fill resin composites should be applied on dentin after application of adhesive resin to decrease shrinkage.

Entities:  

Keywords:  Adhesion; Adhesive resin; Bulk-fill resin composite; Micro-CT; Polymerisation shrinkage

Year:  2019        PMID: 31346784     DOI: 10.1007/s00784-019-03025-5

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  6 in total

1.  Polymerization shrinkage and shrinkage stress of bulk-fill and non-bulk-fill resin-based composites.

Authors:  Peng Yu; Yong-Xiang Xu; Yu-Shu Liu
Journal:  J Dent Sci       Date:  2021-12-23       Impact factor: 3.719

2.  Influence of Practitioner-Related Placement Variables on the Compressive Properties of Bulk-Fill Composite Resins-An In Vitro Clinical Simulation Study.

Authors:  Tamar Brosh; Moshe Davidovitch; Avi Berg; Aviran Shenhav; Raphael Pilo; Shlomo Matalon
Journal:  Materials (Basel)       Date:  2022-06-17       Impact factor: 3.748

3.  Multifunctional Bioactive Resin for Dental Restorative Materials.

Authors:  Loredana Tammaro; Anna Di Salle; Anna Calarco; Ilenia De Luca; Francesco Riccitiello; Gianfranco Peluso; Vittoria Vittoria; Andrea Sorrentino
Journal:  Polymers (Basel)       Date:  2020-02-05       Impact factor: 4.329

4.  Demineralization prevention with a new antibacterial restorative composite containing QASi nanoparticles: an in situ study.

Authors:  Peter Rechmann; Charles Q Le; Benjamin W Chaffee; Beate M T Rechmann
Journal:  Clin Oral Investig       Date:  2021-02-19       Impact factor: 3.573

5.  Micro-computed tomography for assessing the internal and external voids of bulk-fill composite restorations: A technical report.

Authors:  Vincenzo Tosco; Riccardo Monterubbianesi; Michele Furlani; Alessandra Giuliani; Angelo Putignano; Giovanna Orsini
Journal:  Imaging Sci Dent       Date:  2022-06-02

6.  Nano-CT as tool for characterization of dental resin composites.

Authors:  Håvard J Haugen; Saad B Qasim; Jukka P Matinlinna; Pekka Vallittu; Liebert Parreiras Nogueira
Journal:  Sci Rep       Date:  2020-09-23       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.