| Literature DB >> 31346213 |
Ivette Buendia-Roldan1, Nancy Machuca1, Mayra Mejía1, Mariel Maldonado1, Annie Pardo2, Moises Selman3.
Abstract
Interstitial lung abnormalities (ILA) represent aging-associated bilateral interstitial abnormalities in nondependent areas of the lung. However, the aging mechanisms associated with ILA remain uncertain. α-Klotho is an anti-aging molecule that decreases progressively with age, and abnormally low circulating levels of this protein have been revealed in several chronic-degenerative diseases. In this study, we evaluated α-Klotho serum concentrations in individuals with ILA, and examined whether its levels were associated with pulmonary function decline. α-Klotho was measured by ELISA in 50 respiratory asymptomatic adults with ILA and 150 healthy individuals over 60 years. Compared with controls, ILA subjects were predominantly older males, and showed lower lung diffusing capacity (DLCO), higher desaturation after exercise, and higher concentrations of serum matrix metalloprotease-7 (6.24 ± 4.1 versus 4.3 ± 1.7 ng/ml; p = 0.002). No differences were found in serum concentrations of α-Klotho. However, lower levels of this protein in ILA significantly correlated with lower values of forced vital capacity (Rho = 0.39; p = 0.005), forced expiratory volume in one second (Rho = 0.39; p = 0.005), and DLCO (Rho = 0.29, p = 0.04). These findings suggest that decreased concentrations of α-Klotho may be a predictive biomarker of accelerated decline of lung function in individuals with ILA.Entities:
Mesh:
Substances:
Year: 2019 PMID: 31346213 PMCID: PMC6658567 DOI: 10.1038/s41598-019-47199-0
Source DB: PubMed Journal: Sci Rep ISSN: 2045-2322 Impact factor: 4.379
Demographic and functional characteristics.
| Variable | ILA (n = 50) | Control (n = 150) | p value |
|---|---|---|---|
| Male, n (%) | 22 (44) | 41 (27) | 0.03 |
| Age, years, mean (SD) | 73 (±9) | 69 (±8) | 0.05 |
| BMI, kg/m2, mean (SD) | 27 (±4) | 27 (±4) | 0.15 |
| Smoking, n (%) | 22 (44) | 53 (35) | 0.31 |
| MMP-7 serum concentration, mean (SD); ng/ml | 6.24 (±4.1) | 4.3 (±1.7) | 0.002 |
| FEV1, L, mean (SD) | 2.1 (±0.5) | 2.3 (±1.7) | 0.38 |
| FEV1, % predicted | 99 (±16.5) | 102 (±20.1) | 0.36 |
| FVC, L, mean (SD) | 2.7 (±0.7) | 2.8 (±0.8) | 0.40 |
| FVC, % predicted, mean (SD) | 93 (±14.6) | 96 (±18.8) | 0.20 |
| DLCO, % predicted, mean (SD) | 96 (±23) | 115 (±22.3) | <0.001 |
| SpO2 rest, %, mean (SD) | 94 (±2.0) | 94.2 (±2.2) | 0.32 |
| SpO2 exercise, %, mean (SD) | 87.5 (±7.6) | 91.6 (±5.6) | <0.001 |
| 6MWT, meters, mean (SD) | 404 (±146.1) | 439 (±119) | 0.09 |
BMI: Body mass Index, MMP-7: Matrix metalloprotease-7, FEV: Forced expiratory volume in 1 second, FVC: Forced vital capacity, DL: Diffusing capacity of the lung for carbon monoxide, SpO: Blood oxygen saturation, 6MWT: 6-minute walk test. Pulmonary Function Tests were performed at 2440 mts of altitude.
Figure 1Spearman correlation between α-Klotho serum concentrations and forced vital capacity (FVC) (A), and diffusing capacity of the lung for carbon monoxide (DLCO) % predicted (B). Inserted lines represent regression line.