A sensitive gas chromatographic-electron-capture detection method for the simultaneous determination of the antianginal drug nitroglycerin (GTN) and its dinitrate metabolites (1,2-GDN and 1,3-GDN) was developed. Human plasma samples (1 ml) spiked with 2,6-dinitrotoluene as the internal standard were extracted once with 10 ml of a methylene chloride-pentane mixture (3:7, v/v). Using this solvent system, less contaminants are extracted into the organic phase from plasma, resulting in cleaner chromatograms and prolonged column life. A break point was observed on the standard curves of GTN and GDNs. The two linear regions for the detectable concentrations of GTN are 0.025-0.3 and 0.3-3 ng/ml and for 1,2-GDN and 1,3-GDN they are 0.1-1 and 1-10 ng/ml. The limits of detection by this method for GTN, 1,2-GDN and 1,3-GDN in plasma are 0.025, 0.1 and 0.1 ng/ml, respectively.Entities:
Mesh:
Substances:
Year: 1988 PMID: 3134385 DOI: 10.1016/s0378-4347(00)81954-4