Literature DB >> 3134133

Angiographic features associated with percutaneous balloon valvotomy for pulmonary valve stenosis.

P E Burrows1, L N Benson, J S Smallhorn, C A Moes, R M Freedom, F A Burrows, R D Rowe.   

Abstract

Changes in the mobility of the pulmonary valve were determined by a retrospective review of right ventricular cineangiograms from 25 balloon pulmonary valvotomy (BV) procedures in 23 infants and children. The angiographic changes were compared with the post-BV catheter and Doppler pressure gradients across the right ventricular outflow tract. Angiographic features felt to indicate valve tearing were present following 17 of 25 procedures and included increased excursion or straightening of leaflets, localized change in leaflet motion (flail leaflet), and the presence of an additional contrast jet through the valve. There was no statistically significant relationship between any of the angiographic parameters and the pressure data. Most patients with marked increase in angiographic valve mobility had low residual right ventricular to pulmonary artery gradients. However, the absence of angiographic change was not always associated with a high residual gradient.

Entities:  

Mesh:

Year:  1988        PMID: 3134133     DOI: 10.1007/bf02577071

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  11 in total

1.  The dysplastic pulmonary valve: a new roentgenographic entity; with a discussion of the anatomy and radiology of other types of valvular pulmonary stenosis.

Authors:  R F Jeffery; J H Moller; K Amplatz
Journal:  Am J Roentgenol Radium Ther Nucl Med       Date:  1972-02

2.  Percutaneous balloon valvuloplasty for congenital pulmonary valve stenosis.

Authors:  J C Corbelli; R Sterba; D S Moodie
Journal:  Cleve Clin Q       Date:  1984

3.  Percutaneous balloon valvuloplasty for pulmonic valve stenosis in the adult.

Authors:  C J Pepine; I H Gessner; R L Feldman
Journal:  Am J Cardiol       Date:  1982-12       Impact factor: 2.778

4.  Percutaneous balloon valvuloplasty: a new method for treating congenital pulmonary-valve stenosis.

Authors:  J S Kan; R I White; S E Mitchell; T J Gardner
Journal:  N Engl J Med       Date:  1982-08-26       Impact factor: 91.245

5.  Percutaneous balloon valvuloplasty for treatment of congenital pulmonary valvular stenosis in children.

Authors:  A P Rocchini; D A Kveselis; D Crowley; M Dick; A Rosenthal
Journal:  J Am Coll Cardiol       Date:  1984-04       Impact factor: 24.094

6.  Assessment of percutaneous balloon pulmonary and aortic valvuloplasty.

Authors:  J T Walls; Z Lababidi; J J Curtis; D Silver
Journal:  J Thorac Cardiovasc Surg       Date:  1984-09       Impact factor: 5.209

7.  Percutaneous balloon pulmonary valvuloplasty.

Authors:  Z Lababidi; J R Wu
Journal:  Am J Cardiol       Date:  1983-09-01       Impact factor: 2.778

8.  Percutaneous balloon pulmonary valvuloplasty.

Authors:  M Tynan; E J Baker; J Rohmer; O D Jones; J F Reidy; M C Joseph; J Ottenkamp
Journal:  Br Heart J       Date:  1985-05

9.  "Balloon valvulotomy" of congenital pulmonary valve stenosis with tricuspid valve insufficiency.

Authors:  B K Semb; S Tjönneland; G Stake; G Aabyholm
Journal:  Cardiovasc Radiol       Date:  1979-11

10.  Percutaneous transluminal balloon pulmonary valvuloplasty for the relief of pulmonary valve stenosis with special reference to double-balloon technique.

Authors:  M A Ali Khan; S A Yousef; C E Mullins
Journal:  Am Heart J       Date:  1986-07       Impact factor: 4.749

View more
  1 in total

1.  Pulmonary artery tears following balloon valvotomy for pulmonary stenosis.

Authors:  P E Burrows; L N Benson; C A Moes; R M Freedom
Journal:  Cardiovasc Intervent Radiol       Date:  1989 Jan-Feb       Impact factor: 2.740

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.