Literature DB >> 3134132

Radiation exposure of personnel during digital subtraction angiography.

C A Britton1, M H Wholey.   

Abstract

Radiation exposure to the lens of physicians performing intravenous and hand-injected intraarterial digital subtraction angiography (DSA) were monitored with and without a combined face and body shield. Shielding provided nearly a three-fold reduction in dose for both intravenous and intraarterial exams, with the highest doses recorded for intraarterial exams due to longer fluoroscopy and exposure during imaging. When compared with the NCRP guidelines of maximum exposure to the lens, an angiographer could theoretically perform up to two intraarterial and 14 intravenous studies per day with protection or one intraarterial and two intravenous studies per day without protection. The exposure values in this study reflect our equipment and personal technique in carotid DSA and may not apply to other departments, but should encourage other angiographers to monitor exposure in their own angiography suites.

Mesh:

Year:  1988        PMID: 3134132     DOI: 10.1007/bf02577070

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  6 in total

1.  Exposure of the radiologist to scattered radiation during angiography.

Authors:  C B Santen; K Kan; H J Velthuyse; H W Julius
Journal:  Radiology       Date:  1975-05       Impact factor: 11.105

2.  Clinical dosimetry during the angiographic examination. Comments on coronary arteriography.

Authors:  M H Wholey
Journal:  Circulation       Date:  1974-09       Impact factor: 29.690

3.  Evaluation of physician exposure during cardiac catheterization.

Authors:  G J Wold; R V Scheele; S K Agarwal
Journal:  Radiology       Date:  1971-04       Impact factor: 11.105

4.  Radiation exposure to personnel during cardiac catheterization. A preliminary study.

Authors:  S J Malsky; B Roswit; C B Reid; J Haft
Journal:  Radiology       Date:  1971-09       Impact factor: 11.105

5.  Patient doses during digital subtraction angiography of the carotid arteries: comparison with conventional angiography.

Authors:  W Pavlicek; M A Weinstein; M T Modic; E Buonocore; P M Duchesneau
Journal:  Radiology       Date:  1982-12       Impact factor: 11.105

6.  Personnel exposure to radiation at some angiographic procedures.

Authors:  M Gustafsson; A Lunderquist
Journal:  Radiology       Date:  1981-09       Impact factor: 11.105

  6 in total
  3 in total

1.  Radiation dose in vertebroplasty.

Authors:  A Mehdizade; K O Lovblad; K E Wilhelm; T Somon; S G Wetzel; A D Kelekis; H Yilmaz; G Abdo; J B Martin; J M Viera; D A Rüfenacht
Journal:  Neuroradiology       Date:  2004-02-14       Impact factor: 2.804

2.  Radiation exposure to the primary operator during endovascular surgical neuroradiology procedures.

Authors:  K F Layton; D F Kallmes; H J Cloft; B A Schueler; G M Sturchio
Journal:  AJNR Am J Neuroradiol       Date:  2006-04       Impact factor: 3.825

3.  [Status of the captopril test in the diagnosis of hypertension].

Authors:  S Degenhardt; H Friedrich; G Wambach; J H Fischer; W Gross-Fengels; A Linden; K F Neufang; W Hummerich
Journal:  Klin Wochenschr       Date:  1989-11-03
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.