Literature DB >> 3134070

Automated measurement of the concentration and 13C enrichment of carbon dioxide in breath and blood samples using the Finnigan MAT Breath Gas Analysis System.

C M Scrimgeour1, M J Rennie.   

Abstract

The operation and performance of the Finnigan MAT automated Breath Gas Analysis System for the routine analysis of 13C breath tests taken in 20-ml Vacutainers is described. Up to four samples per hour can be analysed with a standard deviation of delta 13C of less than 0.05% being achieved over the range 10-50 mumol CO2. The equipment can also be used for the automatic measurement of the concentration and 13C enrichment of CO2 derived from carbonate or bicarbonate solutions, including blood and other physiological fluids.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3134070     DOI: 10.1002/bms.1200150703

Source DB:  PubMed          Journal:  Biomed Environ Mass Spectrom        ISSN: 0887-6134


  6 in total

1.  Body water measurement in growth disorders: a comparison of bioelectrical impedance and skinfold thickness techniques with isotope dilution.

Authors:  J W Gregory; S A Greene; C M Scrimgeour; M J Rennie
Journal:  Arch Dis Child       Date:  1991-02       Impact factor: 3.791

2.  Changes in body composition and energy expenditure after six weeks' growth hormone treatment.

Authors:  J W Gregory; S A Greene; R T Jung; C M Scrimgeour; M J Rennie
Journal:  Arch Dis Child       Date:  1991-05       Impact factor: 3.791

3.  Inability to stimulate skeletal muscle or whole body protein synthesis in type 1 (insulin-dependent) diabetic patients by insulin-plus-glucose during amino acid infusion: studies of incorporation and turnover of tracer L-[1-13C]leucine.

Authors:  W M Bennet; A A Connacher; K Smith; R T Jung; M J Rennie
Journal:  Diabetologia       Date:  1990-01       Impact factor: 10.122

4.  Fat utilization during exercise: adaptation to a fat-rich diet increases utilization of plasma fatty acids and very low density lipoprotein-triacylglycerol in humans.

Authors:  J W Helge; P W Watt; E A Richter; M J Rennie; B Kiens
Journal:  J Physiol       Date:  2001-12-15       Impact factor: 5.182

5.  Evaluation of 13C-urea breath test in the detection of Helicobacter pylori and in monitoring the effect of tripotassium dicitratobismuthate in non-ulcer dyspepsia.

Authors:  S Dill; J J Payne-James; J J Misiewicz; G K Grimble; D McSwiggan; K Pathak; A J Wood; C M Scrimgeour; M J Rennie
Journal:  Gut       Date:  1990-11       Impact factor: 23.059

6.  Intradialytic parenteral nutrition improves protein and energy homeostasis in chronic hemodialysis patients.

Authors:  Lara B Pupim; Paul J Flakoll; John R Brouillette; Deanna K Levenhagen; Raymond M Hakim; T Alp Ikizler
Journal:  J Clin Invest       Date:  2002-08       Impact factor: 14.808

  6 in total