Jing Dong1, Yaqin Zhang2, Jing Zhou2, Suhua Zhang2, Bin Sun2, Maolong Tang3, Xiaogang Wang2. 1. Department of Ophthalmology, the First Hospital of Shanxi Medical University, Taiyuan, Shanxi, China. 2. Department of Cataract, Shanxi Eye Hospital, Taiyuan, Shanxi, China; and. 3. Casey Eye Institute, Oregon Health and Science University, Portland, OR.
Abstract
PURPOSE: Using Scheimpflug tomography to investigate the difference in corneal power and corneal astigmatism between 3- and 4-mm diameter zones centered on the pupil and corneal apex. METHODS: A total of 90 eyes were included in this study. Axial keratometry, total refractive power, and true net power centered on the pupil and corneal apex in 3- and 4-mm diameter zones were assessed. The paired sample t test and independent sample t test were used for data comparison. RESULTS: For corneal power and corneal astigmatism for the 3- and 4-mm diameter zones, the flat K values of axial keratometry, total refractive power, and true net power centered on the pupil (3-mm: 43.99 ± 1.69 D, 43.12 ± 1.71 D, 42.53 ± 1.67 D; 4-mm: 44.04 ± 1.67 D, 43.38 ± 1.71 D, 42.61 ± 1.65 D) were significantly higher than those centered on the apex (3-mm: 43.93 ± 1.69 D, 43.05 ± 1.71 D, 42.46 ± 1.67 D; 4-mm: 44.01 ± 1.67 D, 43.34 ± 1.69 D, 42.58 ± 1.65 D; all P < 0.02). However, the steep K and astigmatism magnitude values centered on the pupil (3-mm: 45.71 ± 1.73 D, 45.01 ± 1.73 D, 44.38 ± 1.69 D; 1.72 ± 0.83 D, 1.89 ± 0.86 D, 1.85 ± 0.84 D; 4-mm: 45.78 ± 1.73 D, 45.28 ± 1.74 D, 44.45 ± 1.68 D; 1.73 ± 0.84 D, 1.90 ± 0.85 D, 1.84 ± 0.85 D) were lower than those centered on the apex (3-mm: 45.81 ± 1.74 D, 45.10 ± 1.72 D, 44.50 ± 1.70 D; 1.88 ± 0.90 D, 2.05 ± 0.90 D, 2.04 ± 0.90 D; 4-mm: 45.85 ± 1.73 D, 45.34 ± 1.73 D, 44.51 ± 1.69 D; 1.83 ± 0.88 D, 2.00 ± 0.90 D, 1.93 ± 0.86 D; all P < 0.01). Compared with the 3-mm diameter zone, the corresponding 4-mm diameter zone showed higher corneal power centered on both pupil and corneal apex. CONCLUSIONS: The difference in corneal power and corneal astigmatism, measured at 3 and 4 mm, centered on the pupil and the corneal apex should be noted in corneal refractive surgery and toric intraocular lens calculation.
PURPOSE: Using Scheimpflug tomography to investigate the difference in corneal power and corneal astigmatism between 3- and 4-mm diameter zones centered on the pupil and cornealapex. METHODS: A total of 90 eyes were included in this study. Axial keratometry, total refractive power, and true net power centered on the pupil and cornealapex in 3- and 4-mm diameter zones were assessed. The paired sample t test and independent sample t test were used for data comparison. RESULTS: For corneal power and corneal astigmatism for the 3- and 4-mm diameter zones, the flat K values of axial keratometry, total refractive power, and true net power centered on the pupil (3-mm: 43.99 ± 1.69 D, 43.12 ± 1.71 D, 42.53 ± 1.67 D; 4-mm: 44.04 ± 1.67 D, 43.38 ± 1.71 D, 42.61 ± 1.65 D) were significantly higher than those centered on the apex (3-mm: 43.93 ± 1.69 D, 43.05 ± 1.71 D, 42.46 ± 1.67 D; 4-mm: 44.01 ± 1.67 D, 43.34 ± 1.69 D, 42.58 ± 1.65 D; all P < 0.02). However, the steep K and astigmatism magnitude values centered on the pupil (3-mm: 45.71 ± 1.73 D, 45.01 ± 1.73 D, 44.38 ± 1.69 D; 1.72 ± 0.83 D, 1.89 ± 0.86 D, 1.85 ± 0.84 D; 4-mm: 45.78 ± 1.73 D, 45.28 ± 1.74 D, 44.45 ± 1.68 D; 1.73 ± 0.84 D, 1.90 ± 0.85 D, 1.84 ± 0.85 D) were lower than those centered on the apex (3-mm: 45.81 ± 1.74 D, 45.10 ± 1.72 D, 44.50 ± 1.70 D; 1.88 ± 0.90 D, 2.05 ± 0.90 D, 2.04 ± 0.90 D; 4-mm: 45.85 ± 1.73 D, 45.34 ± 1.73 D, 44.51 ± 1.69 D; 1.83 ± 0.88 D, 2.00 ± 0.90 D, 1.93 ± 0.86 D; all P < 0.01). Compared with the 3-mm diameter zone, the corresponding 4-mm diameter zone showed higher corneal power centered on both pupil and cornealapex. CONCLUSIONS: The difference in corneal power and corneal astigmatism, measured at 3 and 4 mm, centered on the pupil and the cornealapex should be noted in corneal refractive surgery and toric intraocular lens calculation.