Literature DB >> 31335368

The Effects of Nitric Oxide in Oxygenator Sweep Gas During Extracorporeal Circulation in a Neonatal Ovine Model.

Avery C Rossidis1, Kendall M Lawrence1, Ali Y Mejaddam1, Aimee G Kim1, Heron D Baumgarten1, Barbara E Coons1, Kathleen Young1, Stylianos Monos1, Grace Hwang1, Alan W Flake1, Marcus G Davey1.   

Abstract

Extracorporeal membrane oxygenation is a life-saving intervention, but bleeding complications are frequent. Given that the combination of platelet loss and dysfunction is a major contributor to this acquired bleeding diathesis, efforts to combat these phenomena are of great clinical importance. In this study, we investigated the effects of nitric oxide (NO) added to the sweep gas of an extracorporeal circuit in a neonatal ovine model. Eight lambs (age 9.6 ± 1.9 days) were cannulated via the neck vessels and maintained on a pumpless arteriovenous extracorporeal membrane oxygenation circuit with blood flow restricted to 100 ml/min for 72 hours. All animals were heparinized, and a subset (n = 4) also received NO in the sweep gas at a concentration of 200 ppm. We observed no adverse effects from NO administration, and methemoglobin levels remained unchanged. Platelet counts significantly declined in all animals over the course of the study; however, mean counts were higher in the NO-treated group, and this difference was statistically significant at 24 hours (62 ± 3% vs. 32 ± 7% of baseline, P < 0.01). Likewise, mean plasma levels of beta-thromboglobulin, a marker of platelet activation, were lower in the NO-treated group, and this difference was also significant at the 24 hour time point (9.5 ± 2.2 vs. 19.7 ± 6.5 pg/mL/10 platelets, P < 0.05). We conclude that 200 ppm NO can be safely blended into the oxygenator sweep gas of a low-flow extracorporeal circuit and that it may transiently attenuate platelet consumption and activation.

Entities:  

Mesh:

Substances:

Year:  2020        PMID: 31335368     DOI: 10.1097/MAT.0000000000001047

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  2 in total

1.  A pumpless artificial lung without systemic anticoagulation: The Nitric Oxide Surface Anticoagulation system.

Authors:  Brian P Fallon; Orsolya Lautner-Csorba; Alex J Thompson; Gergely Lautner; Adrianna Kayden; Matthew D Johnson; Stephen L Harvey; Mark W Langley; Alvaro Rojas Peña; Robert H Bartlett; Ronald B Hirschl
Journal:  J Pediatr Surg       Date:  2021-09-20       Impact factor: 2.545

Review 2.  Pediatric and neonatal extracorporeal life support: current state and continuing evolution.

Authors:  Brian P Fallon; Samir K Gadepalli; Ronald B Hirschl
Journal:  Pediatr Surg Int       Date:  2021-01-01       Impact factor: 1.827

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.