Literature DB >> 31333015

PVC-Based Ion-Selective Electrodes with a Silicone Rubber Outer Coating with Improved Analytical Performance.

Narender Kumar Joon1, Ning He1, Tautgirdas Ruzgas2, Johan Bobacka1, Grzegorz Lisak3,4.   

Abstract

An outer layer of pure silicone rubber (SR), i.e. SR without any plasticizer, ionophore, or lipophilic anion, was applied on top of a conventional poly(vinyl chloride) (PVC) based K+-selective membrane in a solid-contact ion-selective electrode (SC-ISE). The influence of the outer SR coating on the analytical performance of the K+-ISEs was studied. The presence of the SR coating did not affect the selectivity of the SC-ISE, indicating that the plasticizer, ionophore, and lipophilic anion are spontaneously distributed from the PVC-based membrane into the SR layer. This was confirmed by electrochemical impedance spectroscopy (EIS). Interestingly, the reproducibility of the standard potential of the conditioned SC-ISE was significantly improved from E0 ± 35.3 mV to E0 ± 3.5 mV simply by adding the SR coating on top of the plasticized PVC based K+-selective membrane. Moreover, the adsorption of bovine serum albumin (BSA) was significantly reduced at the SR coated ion-selective membrane. Thus, the addition of a SR coating on a plasticized PVC ion-selective membrane seems to be a feasible method to improve the analytical performance and to reduce the biofouling of potentiometric ion sensors.

Entities:  

Year:  2019        PMID: 31333015     DOI: 10.1021/acs.analchem.9b01490

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  6 in total

1.  Hydrophobic laser-induced graphene potentiometric ion-selective electrodes for nitrate sensing.

Authors:  Robert G Hjort; Raquel R A Soares; Jingzhe Li; Dapeng Jing; Lindsey Hartfiel; Bolin Chen; Bryan Van Belle; Michelle Soupir; Emily Smith; Eric McLamore; Jonathan C Claussen; Carmen L Gomes
Journal:  Mikrochim Acta       Date:  2022-02-26       Impact factor: 5.833

2.  Comparison of Different Commercial Conducting Materials as Ion-to-Electron Transducer Layers in Low-Cost Selective Solid-Contact Electrodes.

Authors:  C Ocaña; M Muñoz-Correas; N Abramova; A Bratov
Journal:  Sensors (Basel)       Date:  2020-02-29       Impact factor: 3.576

Review 3.  Forward-Looking Roadmaps for Long-Term Continuous Water Quality Monitoring: Bottlenecks, Innovations, and Prospects in a Critical Review.

Authors:  Yuankai Huang; Xingyu Wang; Wenjun Xiang; Tianbao Wang; Clifford Otis; Logan Sarge; Yu Lei; Baikun Li
Journal:  Environ Sci Technol       Date:  2022-04-20       Impact factor: 11.357

4.  Ion-Selective Electrode Based on a Novel Biomimetic Nicotinamide Compound for Phosphate Ion Sensor.

Authors:  Bongjin Jeong; Jin Seong Oh; Do Yeob Kim; Dong Gyu Kim; Young Il Kim; Jungseok Heo; Hyung-Kun Lee
Journal:  Polymers (Basel)       Date:  2022-08-19       Impact factor: 4.967

5.  In Vivo Sensing of pH in Tomato Plants Using a Low-Cost and Open-Source Device for Precision Agriculture.

Authors:  Antonio Ruiz-Gonzalez; Harriet Kempson; Jim Haseloff
Journal:  Biosensors (Basel)       Date:  2022-06-23

6.  Solid-Contact Potentiometric Anion Sensing Based on Classic Silver/Silver Insoluble Salts Electrodes without Ion-Selective Membrane.

Authors:  Chunxian Liao; Lijie Zhong; Yitian Tang; Zhonghui Sun; Kanglong Lin; Longbin Xu; Yan Lyu; Dequan He; Ying He; Yingming Ma; Yu Bao; Shiyu Gan; Li Niu
Journal:  Membranes (Basel)       Date:  2021-12-05
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.