Literature DB >> 31332115

Commentary: Clinical outcome of a nonvalved Aurolab aqueous drainage implant in posterior segment versus anterior chamber.

Manish Panday1.   

Abstract

Entities:  

Mesh:

Year:  2019        PMID: 31332115      PMCID: PMC6677069          DOI: 10.4103/ijo.IJO_873_19

Source DB:  PubMed          Journal:  Indian J Ophthalmol        ISSN: 0301-4738            Impact factor:   1.848


× No keyword cloud information.
The decision for an implant in glaucoma is usually reserved for either of the 2 conditions—either conventional trabeculectomy is likely to fail or has failed.[1] Implants provide an equatorial reservoir of aqueous through a permanent sclerostomy using a tube attached to a plate whose size determines the surface area of drainage. The basic tenet of placing a tube in the posterior segment (PS) requires thorough vitrectomy to prevent tube closure by vitreous tags. Maheshwari et al. found marginally better success rates at 1 year for anterior segment placement although the risks of complications were higher in the PS placement.[2] In this study, tube placement in PS was done if “concurrent” vitrectomy was done.[2] The posterior placement can also be a staged procedure especially if a tamponading agent is needed in the initial retinal surgery. Uncomplicated pars plana vitrectomy (PPV) in itself can also cause secondary open-angle glaucoma.[1] This is postulated because of increased oxygen tension and consequent oxidative damage to the trabecular meshwork.[3] Lens extraction is considered to be a strong risk factor for open-angle glaucoma following uncomplicated PPV.[3] It is important to consider baseline clinical status to ascertain the outcomes of a study. The majority (44%) of subjects in the PS group in this study had traumatic glaucoma. The PS group also had higher preoperative intra ocular pressure (IOP) and required more antiglaucoma medications. This coupled with pars plana vitrectomy may itself influence IOP in the PS group. The 2 most commonly used implants in the world are Ahmed glaucoma valve (AGV) and Baerveldt glaucoma implant (BGI).[4] The aurolab aqueous drainage implant (AADI) provides a low-cost comparable alternative to Baerveldt. Having a larger surface area than AGV (350 vs 184 mm2) and a nonvalved design, implants like BGI or AADI have less likely potential for bleb encapsulation as the tube ligature prevents inflammatory mediators to escape. Although both approaches can be used, the pars plana approach gives an advantage of avoiding tube-related complications (such as tube-cornea touch) and endothelial decompensation in select cases. Another approach could be the ciliary sulcus in eyes with pseudophakia or corneal diseases.[5] A meta-analysis by Wang et al. involving 275 eyes in 4 retrospective studies found similar efficacy of reduction of IOP (weighted mean difference [WMD] –1.01 mm Hg; P = 0.52) between pars plana and anterior chamber glaucoma drainage devices.[6] Similarly, the WMD for glaucoma medication reduction was 0.23 (P = 0.19).[6] Similar trial results should be interpreted keeping in mind potential selection bias because of retrospective nature and different clinical indications for anterior and posterior placements of glaucoma drainage devices. Of particular interest would be to observe the effect on endothelial cell counts in a randomized clinical trial for a larger sample.
  6 in total

1.  Baerveldt glaucoma implant insertion in the posterior chamber sulcus.

Authors:  Celso Tello; Edgar M Espana; Ricardo Mora; Syril Dorairaj; Jeffrey M Liebmann; Robert Ritch
Journal:  Br J Ophthalmol       Date:  2007-02-14       Impact factor: 4.638

2.  Long-Term Changes in Intraocular Pressure after Vitrectomy for Rhegmatogenous Retinal Detachment, Epi-Retinal Membrane, or Macular Hole.

Authors:  Kentaro Yamamoto; Takeshi Iwase; Hiroko Terasaki
Journal:  PLoS One       Date:  2016-11-29       Impact factor: 3.240

Review 3.  Comparison of pars plana with anterior chamber glaucoma drainage device implantation for glaucoma: a meta-analysis.

Authors:  Bin Wang; Wenwei Li
Journal:  BMC Ophthalmol       Date:  2018-08-29       Impact factor: 2.209

4.  Influence of Vitrectomy-related Factors on the Outcome of Ahmed Glaucoma Valve Implantation.

Authors:  Jaehyuck Jo; Kyung Rim Sung; Yoon Jeon Kim
Journal:  Korean J Ophthalmol       Date:  2018-10

5.  Clinical outcome of a nonvalved Aurolab aqueous drainage implant in posterior segment versus anterior chamber.

Authors:  Devendra Maheshwari; Shylesh Dabke; Sindhushree Rajagopal; Mohideen A Kadar; Rengappa Ramakrishnan
Journal:  Indian J Ophthalmol       Date:  2019-08       Impact factor: 1.848

6.  Intermediate-term outcome of Aurolab aqueous drainage implant.

Authors:  Reji Philip; Premanand Chandran; Nabeed Aboobacker; Mrunali Dhavalikar; Ganesh V Raman
Journal:  Indian J Ophthalmol       Date:  2019-02       Impact factor: 1.848

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.