Literature DB >> 31331655

A low transition temperature mixture for the dispersive liquid-liquid microextraction of pesticides from surface waters.

Pierpaolo Tomai1, Anna Lippiello1, Paola D'Angelo1, Ingmar Persson2, Andrea Martinelli1, Valerio Di Lisio1, Roberta Curini1, Chiara Fanali3, Alessandra Gentili4.   

Abstract

This paper illustrates the development of a procedure based on the use of a low transition temperature mixture (LTTM) for the dispersive liquid-liquid microextraction (DLLME) of fungicides, insecticides and acaricides from surface waters. The LTTM preparation involves the heat-mixing of choline chloride and acetylsalicylic acid in a molar ratio 1:2 (ChCl(ASA)2). The resulting mixture appears as a clear viscous liquid at room-temperature, denser than water (1.20 ± 0.01 g mL-1). For its characterization, differential scanning calorimetry (DSC) provided crucial evidence to classify it as a LTTM rather than as a deep eutectic solvent (DES) since it revealed an intense glass transition at -37 °C. Large-angle X-ray scattering (LAXS) confirmed the lack of any long-distance order. Due to the LTTM immiscibility with water, an evaluation study was carried out to test ChCl(ASA)2 as an effective alternative to the conventional chlorinated solvents for DLLME. To this end, 24 pesticides were used as model compounds, extracted from surface water samples (5 mL) and analyzed by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). The definitive procedure required the optimization of some key parameters such as volume of extracting solvent, type and volume of dispersing solvent, volume of the aqueous sample, LTTM dispersion procedure, and extraction time. Depending on pKa and logP values, recoveries ranged from 18 (for very polar compounds) to 96%, revealing that the ideal candidates for the extraction with ChCl(ASA)2 are neutral compounds with logP >2. After complete validation, the method was applied to analyze water samples from the River Tiber where dodine and dimetomorph were found at low μg L-1 concentration levels.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Deep eutectic solvents; Dispersive liquid-liquid microextraction; Environmental samples; LC–MS; Low transition temperature mixture; Sample preparation

Mesh:

Substances:

Year:  2019        PMID: 31331655     DOI: 10.1016/j.chroma.2019.06.050

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  3 in total

1.  Hydrophobic Eutectic Solvent-Based Dispersive Liquid-Liquid Microextraction Applied to the Analysis of Pesticides in Wine.

Authors:  Chiara Dal Bosco; Francesca Mariani; Alessandra Gentili
Journal:  Molecules       Date:  2022-01-28       Impact factor: 4.411

2.  Dispersive liquid-liquid microextraction, an effective tool for the determination of synthetic cannabinoids in oral fluid by liquid chromatography-tandem mass spectrometry.

Authors:  Pierpaolo Tomai; Alessandra Gentili; Roberta Curini; Rossella Gottardo; Salvatore Fanali
Journal:  J Pharm Anal       Date:  2020-11-19

3.  Application of a Low Transition Temperature Mixture for the Dispersive Liquid-Liquid Microextraction of Illicit Drugs from Urine Samples.

Authors:  Valeria Gallo; Pierpaolo Tomai; Valerio Di Lisio; Chiara Dal Bosco; Paola D'Angelo; Chiara Fanali; Giovanni D'Orazio; Ilaria Silvestro; Yolanda Picó; Alessandra Gentili
Journal:  Molecules       Date:  2021-08-28       Impact factor: 4.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.