Literature DB >> 31323647

Imaging of 99mTc-DMSA and 18F-FDG in humans using a Si/CdTe Compton camera.

Takashi Nakano1, Makoto Sakai, Kota Torikai, Yoshiyuki Suzuki, Shin'ichiro Takeda, Shin-Ei Noda, Mitsutaka Yamaguchi, Yuto Nagao, Mikiko Kikuchi, Hirokazu Odaka, Tomihiro Kamiya, Naoki Kawachi, Shin Watanabe, Kazuo Arakawa, Tadayuki Takahashi.   

Abstract

The Compton camera can simultaneously acquire images of multiple isotopes injected in a body; therefore, it has the potential to introduce a new subfield in the field of biomedical imaging applications. The objective of this study is to assess the ability of a prototype semiconductor-based silicon/cadmium telluride (Si/CdTe) Compton camera to simultaneously image the distributions of technetium (99mTc)-dimercaptosuccinic acid (DMSA) (141 keV emission) and 18F-fluorodeoxyglucose (FDG) (511 keV emission) injected into a human volunteer. 99mTc-DMSA and 18F-FDG were injected intravenously into a 25-year-old male volunteer. The distributions of 99mTc-DMSA and 18F-FDG were simultaneously made visible by setting a specified energy window for each radioisotope. The images of these radiopharmaceuticals acquired using the prototype Compton camera were superimposed onto computed tomography images for reference. The reconstructed image showed that 99mTc-DMSA had accumulated in both kidneys, which is consistent with the well-known diagnostic distribution determined by clinical imaging via single-photon emission computed tomography. In the 18F-FDG image, there is broad distribution around the liver and kidneys, which was expected based on routine clinical positron emission tomography imaging. The current study demonstrated for the first time that the Si/CdTe Compton camera was capable of simultaneously imaging the distributions of two radiopharmaceuticals, 99mTc-DMSA and 18F-FDG, in a human body. These results suggest that the Si/CdTe Compton camera has the potential to become a novel modality for nuclear medical diagnoses enabling multi-probe simultaneous tracking.

Entities:  

Year:  2020        PMID: 31323647     DOI: 10.1088/1361-6560/ab33d8

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  7 in total

1.  Performance demonstration of a hybrid Compton camera with an active pinhole for wide-band X-ray and gamma-ray imaging.

Authors:  Akihisa Omata; Jun Kataoka; Kazuya Fujieda; Shogo Sato; Eri Kuriyama; Hiroki Kato; Atsushi Toyoshima; Takahiro Teramoto; Kazuhiro Ooe; Yuwei Liu; Keiko Matsunaga; Takashi Kamiya; Tadashi Watabe; Eku Shimosegawa; Jun Hatazawa
Journal:  Sci Rep       Date:  2020-08-20       Impact factor: 4.379

2.  Quantitative PET in the 2020s: a roadmap.

Authors:  Steven R Meikle; Vesna Sossi; Emilie Roncali; Simon R Cherry; Richard Banati; David Mankoff; Terry Jones; Michelle James; Julie Sutcliffe; Jinsong Ouyang; Yoann Petibon; Chao Ma; Georges El Fakhri; Suleman Surti; Joel S Karp; Ramsey D Badawi; Taiga Yamaya; Go Akamatsu; Georg Schramm; Ahmadreza Rezaei; Johan Nuyts; Roger Fulton; André Kyme; Cristina Lois; Hasan Sari; Julie Price; Ronald Boellaard; Robert Jeraj; Dale L Bailey; Enid Eslick; Kathy P Willowson; Joyita Dutta
Journal:  Phys Med Biol       Date:  2021-03-12       Impact factor: 4.174

3.  Crosstalk Reduction Using a Dual Energy Window Scatter Correction in Compton Imaging.

Authors:  Makoto Sakai; Raj Kumar Parajuli; Yoshiki Kubota; Nobuteru Kubo; Mitsutaka Yamaguchi; Yuto Nagao; Naoki Kawachi; Mikiko Kikuchi; Kazuo Arakawa; Mutsumi Tashiro
Journal:  Sensors (Basel)       Date:  2020-04-26       Impact factor: 3.576

4.  Carbon range verification with 718 keV Compton imaging.

Authors:  Raj Kumar Parajuli; Makoto Sakai; Kazuo Arakawa; Yoshiki Kubota; Nobuteru Kubo; Mutsumi Tashiro
Journal:  Sci Rep       Date:  2021-11-04       Impact factor: 4.379

5.  Multi-modal 3D imaging of radionuclides using multiple hybrid Compton cameras.

Authors:  Akihisa Omata; Miho Masubuchi; Nanase Koshikawa; Jun Kataoka; Hiroki Kato; Atsushi Toyoshima; Takahiro Teramoto; Kazuhiro Ooe; Yuwei Liu; Keiko Matsunaga; Takashi Kamiya; Tadashi Watabe; Eku Shimosegawa; Jun Hatazawa
Journal:  Sci Rep       Date:  2022-02-15       Impact factor: 4.996

Review 6.  Development and Applications of Compton Camera-A Review.

Authors:  Raj Kumar Parajuli; Makoto Sakai; Ramila Parajuli; Mutsumi Tashiro
Journal:  Sensors (Basel)       Date:  2022-09-28       Impact factor: 3.847

7.  Improved iterative reconstruction method for Compton imaging using median filter.

Authors:  Makoto Sakai; Raj Kumar Parajuli; Yoshiki Kubota; Nobuteru Kubo; Mikiko Kikuchi; Kazuo Arakawa; Takashi Nakano
Journal:  PLoS One       Date:  2020-03-06       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.