Literature DB >> 31323632

Ultrasonographic optic nerve sheath diameter correlation with ICP and accuracy as a tool for noninvasive surrogate ICP measurement in patients with decompressive craniotomy.

Juxiang Wang1,2, Ke Li3, Hongjia Li4, Chengyi Ji2, Ziyao Wu2, Huimin Chen2, Bin Chen5.   

Abstract

OBJECTIVE: Increased intracranial pressure (ICP) results in enlarged optic nerve sheath diameter (ONSD). In this study the authors aimed to assess the association of ONSD and ICP in severe traumatic brain injury (TBI) after decompressive craniotomy (DC).
METHODS: ONSDs were measured by ocular ultrasonography in 40 healthy control adults. ICPs were monitored invasively with a microsensor at 6 hours and 24 hours after DC operation in 35 TBI patients. ONSDs were measured at the same time in these patients. Patients were assigned to 3 groups according to ICP levels, including normal (ICP ≤ 13 mm Hg), mildly elevated (ICP = 14-22 mm Hg), and severely elevated (ICP > 22 mm Hg) groups. ONSDs were compared between healthy control adults and TBI cases with DC. Then, the association of ONSD with ICP was analyzed using Pearson's correlation coefficient, linear regression analysis, and receiver operator characteristic curves.
RESULTS: Seventy ICP measurements were obtained among 35 TBI patients after DC, including 25, 27, and 18 measurements in the normal, mildly elevated, and severely elevated ICP groups, respectively. Mean ONSDs were 4.09 ± 0.38 mm in the control group and 4.92 ± 0.37, 5.77 ± 0.41, and 6.52 ± 0.44 mm in the normal, mildly elevated, and severely elevated ICP groups, respectively (p < 0.001). A significant linear correlation was found between ONSD and ICP (r = 0.771, p < 0.0001). Enlarged ONSD was a robust predictor of elevated ICP. With an ONSD cutoff of 5.48 mm (ICP > 13 mm Hg), sensitivity and specificity were 91.1% and 88.0%, respectively; a cutoff of 5.83 mm (ICP > 22 mm Hg) yielded sensitivity and specificity of 94.4% and 81.0%, respectively.
CONCLUSIONS: Ultrasonographic ONSD is strongly correlated with invasive ICP measurements and may serve as a sensitive and noninvasive method for detecting elevated ICP in TBI patients after DC.

Entities:  

Keywords:  DC; DC = decompressive craniotomy; EVD = external ventricular drainage; GCS = Glasgow Coma Scale; ICP; ICP = intracranial pressure; ONSD; ONSD = optic nerve sheath diameter; ROC = receiver operating characteristic; TBI = traumatic brain injury; US-ONSD = ultrasonographic ONSD; decompressive craniotomy; intracranial pressure; optic nerve sheath diameter; trauma; traumatic brain injury; ultrasonography

Year:  2019        PMID: 31323632     DOI: 10.3171/2019.4.JNS183297

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  8 in total

Review 1.  Non-invasive detection of intracranial pressure related to the optic nerve.

Authors:  Jian Li; Chao Wan
Journal:  Quant Imaging Med Surg       Date:  2021-06

2.  Comment on 'Neuroradiology for ophthalmologists'.

Authors:  Ankit Sinha; Victoria Nowak; Fion Bremner
Journal:  Eye (Lond)       Date:  2021-04-06       Impact factor: 3.775

Review 3.  The role of optic nerve sheath diameter ultrasound in brain infection.

Authors:  Gavin A Stead; Fiona V Cresswell; Samuel Jjunju; Pham K N Oanh; Guy E Thwaites; Joseph Donovan
Journal:  eNeurologicalSci       Date:  2021-02-22

4.  Optic nerve sheath diameter in severe preeclampsia with neurologic features versus controls.

Authors:  Mary E Sterrett; Brittany Austin; Ryan M Barnes; Eugene Y Chang
Journal:  BMC Pregnancy Childbirth       Date:  2022-03-19       Impact factor: 3.007

5.  Comparing ultrasonographic optic nerve sheath diameter to head computed tomography scan to predict intracranial pressure elevation.

Authors:  Shierly Novitawati Sitanaya; Fadhila Kamayanti; Hari Adityo Nugroho; Bobi Prabowo
Journal:  SAGE Open Med       Date:  2022-02-17

6.  Value of Optic Nerve Sheath Diameter in Diagnosis and Follow Up of Patients with Disturbed Conscious Level.

Authors:  Osama Mahmoud Momtaz; Omar M Said; Amany Mahmoud Mohamed; Tamer Sayed Abdel Mawla
Journal:  Eye Brain       Date:  2022-09-27

7.  Effect of 5 different cervical collars on optic nerve sheath diameter: A randomized crossover trial.

Authors:  Michal Ladny; Jacek Smereka; Sanchit Ahuja; Lukasz Szarpak; Kurt Ruetzler; Jerzy Robert Ladny
Journal:  Medicine (Baltimore)       Date:  2020-04       Impact factor: 1.817

8.  Effects of Increased Optic Nerve Sheath Diameter on Inadequate Emergence from Anesthesia in Patients Undergoing Robot-Assisted Laparoscopic Prostatectomy: A Prospective Observational Study.

Authors:  Yu Jeong Bang; Heejoon Jeong; Burn Young Heo; Byung Seop Shin; Woo Seog Sim; Duk-Kyung Kim; Sang Hyun Lee; Ji Su Kim; Young Hee Shin
Journal:  Diagnostics (Basel)       Date:  2021-12-02
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.