Literature DB >> 31321809

k-Space deep learning for reference-free EPI ghost correction.

Juyoung Lee1, Yoseob Han1, Jae-Kyun Ryu2,3, Jang-Yeon Park2,3, Jong Chul Ye1.   

Abstract

PURPOSE: Nyquist ghost artifacts in echo planar imaging (EPI) are originated from phase mismatch between the even and odd echoes. However, conventional correction methods using reference scans often produce erroneous results especially in high-field MRI due to the nonlinear and time-varying local magnetic field changes. Recently, it was shown that the problem of ghost correction can be reformulated as k-space interpolation problem that can be solved using structured low-rank Hankel matrix approaches. Another recent work showed that data driven Hankel matrix decomposition can be reformulated to exhibit similar structures as deep convolutional neural network. By synergistically combining these findings, we propose a k-space deep learning approach that immediately corrects the phase mismatch without a reference scan in both accelerated and non-accelerated EPI acquisitions. THEORY AND METHODS: To take advantage of the even and odd-phase directional redundancy, the k-space data are divided into 2 channels configured with even and odd phase encodings. The redundancies between coils are also exploited by stacking the multi-coil k-space data into additional input channels. Then, our k-space ghost correction network is trained to learn the interpolation kernel to estimate the missing virtual k-space data. For the accelerated EPI data, the same neural network is trained to directly estimate the interpolation kernels for missing k-space data from both ghost and subsampling.
RESULTS: Reconstruction results using 3T and 7T in vivo data showed that the proposed method outperformed the image quality compared to the existing methods, and the computing time is much faster.
CONCLUSIONS: The proposed k-space deep learning for EPI ghost correction is highly robust and fast, and can be combined with acceleration, so that it can be used as a promising correction tool for high-field MRI without changing the current acquisition protocol.
© 2019 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  EPI; MRI; Nyquist ghost artifact; deep convolutional framelet; deep learning k-space learning

Mesh:

Year:  2019        PMID: 31321809     DOI: 10.1002/mrm.27896

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  4 in total

Review 1.  A half-century of innovation in technology-preparing MRI for the 21st century.

Authors:  Peter Börnert; David G Norris
Journal:  Br J Radiol       Date:  2020-06-15       Impact factor: 3.039

2.  Deep learning network for integrated coil inhomogeneity correction and brain extraction of mixed MRI data.

Authors:  Kai-Hsiang Chuang; Pei-Huan Wu; Zengmin Li; Kang-Hsing Fan; Jun-Cheng Weng
Journal:  Sci Rep       Date:  2022-05-20       Impact factor: 4.996

Review 3.  Artificial Intelligence for MR Image Reconstruction: An Overview for Clinicians.

Authors:  Dana J Lin; Patricia M Johnson; Florian Knoll; Yvonne W Lui
Journal:  J Magn Reson Imaging       Date:  2020-02-12       Impact factor: 4.813

4.  Validation of Deep Learning-Based Artifact Correction on Synthetic FLAIR Images in a Different Scanning Environment.

Authors:  Kyeong Hwa Ryu; Hye Jin Baek; Sung-Min Gho; Kanghyun Ryu; Dong-Hyun Kim; Sung Eun Park; Ji Young Ha; Soo Buem Cho; Joon Sung Lee
Journal:  J Clin Med       Date:  2020-01-29       Impact factor: 4.241

  4 in total