Literature DB >> 31315003

Suture Button Versus Hook Plate for Acute Unstable Acromioclavicular Joint Dislocation: A Meta-analysis.

Cong Wang1, Jia-Hong Meng1, Yi-Wen Zhang2, Ming-Min Shi1.   

Abstract

BACKGROUND: Surgical treatment is indicated for unstable acromioclavicular (AC) joint dislocation. The hook plate (HP) technique is a commonly used treatment method, but the use of the suture button (SB) technique is increasing.
PURPOSE: To conduct a meta-analysis of clinical studies evaluating patient outcomes between the SB and HP techniques for acute unstable AC joint dislocation. STUDY
DESIGN: Meta-analysis.
METHODS: A literature search of the Embase, PubMed, and Cochrane Library databases was performed according to the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. Cohort studies and case-control studies comparing the SB and HP procedures for acute unstable AC joint dislocation were included. Statistical analysis was performed with RevMan (v 5.3.5).
RESULTS: Eight clinical studies that met the inclusion criteria were identified and included a total of 204 patients treated with the SB technique and 195 patients with the HP technique. Patients treated with the SB technique had a higher Constant score (mean difference [MD], 3.95; 95% CI, 1.20-6.70; P = .005) and a lower visual analog scale pain score (MD, -0.75; 95% CI, -1.12 to 0.37; P < .0001) when compared with the HP technique. No significant differences in operation time (MD, -0.38; 95% CI, -7.14 to 6.37; P = .91), coracoclavicular distance (MD, -0.07; 95% CI, -0.49 to 0.35; P = .75), complications (odds ratio, 0.59; 95% CI, 0.22-1.54; P = .28), and loss of reduction (odds ratio, 2.55; 95% CI, 0.66-9.83; P = .17) were found between the SB and HP techniques. The subgroup analysis showed that the arthroscopic SB technique resulted in a higher Constant score (MD, 6.75; 95% CI, 4.21-9.29; P < .00001) as compared with the HP technique, but no differences were observed between the open SB and HP techniques (MD, 0.69; 95% CI, -0.82 to 2.20; P = .37).
CONCLUSION: This meta-analysis demonstrated that the SB technique resulted in better functional outcomes and a reduced visual analog scale pain score when compared with the HP technique. However, for operation time, coracoclavicular distance, complications, and loss of reduction, there were no statistically significant differences between the techniques. Compared with the open procedure, arthroscopic SB may be superior for better functional outcomes.

Entities:  

Keywords:  acromioclavicular joint dislocation; arthroscopy; hook plate; meta-analysis; suture button

Year:  2019        PMID: 31315003     DOI: 10.1177/0363546519858745

Source DB:  PubMed          Journal:  Am J Sports Med        ISSN: 0363-5465            Impact factor:   6.202


  4 in total

Review 1.  Biologic and synthetic ligament reconstructions achieve better functional scores compared to osteosynthesis in the treatment of acute acromioclavicular joint dislocation.

Authors:  Maristella F Saccomanno; Giuseppe Sircana; Valentina Cardona; Valeria Vismara; Alessandra Scaini; Andrea G Salvi; Stefano Galli; Giacomo Marchi; Giuseppe Milano
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2020-08-14       Impact factor: 4.342

2.  Clinical outcomes of arthroscopic and navigation-assisted two tunnel technique for coracoclavicular ligament augmentation of acute acromioclavicular joint dislocations.

Authors:  Jan Theopold; Ralf Henkelmann; Claus Zhang; Tobias Schöbel; Georg Osterhoff; Pierre Hepp
Journal:  BMC Musculoskelet Disord       Date:  2021-06-09       Impact factor: 2.362

3.  Glenohumeral Migration of Intraosseous Suture- Button after Acromioclavicular JointACJ Reconstruction - A Case Report.

Authors:  Karan Singh Panesar; Angus Robertson
Journal:  J Orthop Case Rep       Date:  2020 Aug-Sep

Review 4.  Arthroscopic Suture-Button Versus Hook-Plate Fixation for Acromioclavicular Joint Injuries-A Systematic Review of Comparative Studies.

Authors:  Angus J Lloyd; Eoghan T Hurley; Martin S Davey; Leo Pauzenberger; Hannan Mullet
Journal:  Arthrosc Sports Med Rehabil       Date:  2020-09-22