Literature DB >> 31313846

Use of a vascularized dorsal sensory branch of an ulnar nerve flap for repairing a proper digital nerve with coverage of a volar soft tissue defect: Report of two cases.

Satoshi Usami1, Sanshiro Kawahara1, Kohei Inami1, Yuichi Hirase2.   

Abstract

To repair a short nerve gap, autograft, allograft, autogenous, or synthetic conduits are selected, but a vascularized nerve autograft is preferred to obtain a reliable postoperative outcome in the case of an unfavorable wound bed. The purpose of this report is to describe and evaluate two cases of repair of a proper digital nerve and volar soft tissue defect with a vascularized dorsal sensory branch of an ulnar nerve flap. The cases of two men, 40 and 20 years old, who suffered index finger defects due to crush lacerations that required a flap and a nerve graft, are presented. A 4.0 cm × 2.0 cm and a 3.2 cm × 1.6 cm flap, which were nourished by the perforators from the ulnar proper digital artery of the little finger, were elevated from the ulnar side of fifth metacarpal bone head and transferred for coverage of the soft tissue defect. A 4.6-cm and a 3.0-cm vascularized nerve graft was interposed in the nerve gap. The patients' postoperative courses were uneventful, and both patients had no complaints related to the donor site. Static and moving two-point discrimination were 8 and 6 mm, respectively, at 6 months after surgery in the first case and 5 and 3 mm, respectively, at 9 months after surgery in the second case. This flap, which could be elevated in the same operative field with a nerve having similar diameter to that of the proper digital nerve, was useful for repair of a finger volar tissue defect.
© 2019 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2019        PMID: 31313846     DOI: 10.1002/micr.30496

Source DB:  PubMed          Journal:  Microsurgery        ISSN: 0738-1085            Impact factor:   2.425


  3 in total

1.  Electrospun polycaprolactone (PCL)-amnion nanofibrous membrane prevents adhesions and promotes nerve repair in a rat model of sciatic nerve compression.

Authors:  Ruiyi Dong; Chunjie Liu; Siyu Tian; Jiangbo Bai; Kunlun Yu; Lei Liu; Dehu Tian
Journal:  PLoS One       Date:  2020-12-18       Impact factor: 3.240

2.  Unexplored parameters of ulnar nerve in the palm and its clinical implications; A cadaveric study.

Authors:  Rohini Punja; Gaurav Kini; Mamatha Hosapatna
Journal:  Ann Med Surg (Lond)       Date:  2022-01-14

3.  Nerve recovery from treatment with a vascularized nerve graft compared to an autologous non-vascularized nerve graft in animal models: A systematic review and meta-analysis.

Authors:  Berend O Broeren; Liron S Duraku; Caroline A Hundepool; Erik T Walbeehm; J Michiel Zuidam; Carlijn R Hooijmans; Tim De Jong
Journal:  PLoS One       Date:  2021-12-02       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.