Interest in the assessment of the anthropogenic contamination of the marine environment has accelerated in recent years. Existing methods to analyze environmental samples (e.g., sediments or tissues) for trace amounts of organic contaminants such as aromatic hydrocarbons and chlorinated compounds are tedious and costly. We report a rapid, efficient high-performance liquid chromatography (HPLC) procedure which uses a size-exclusion column to separate the analytes of interest from interfering compounds in the sample matrix. Analytical results from the HPLC method were, in general, comparable to a gravity-column method which had been used for several years. The HPLC method had several other advantages: improved precision; the ability to monitor chromatographic conditions; the potential for automating analyses; and reduced consumption of solvents and other materials.Entities:
Mesh:
Substances:
Year: 1988 PMID: 3131379 DOI: 10.1016/s0021-9673(00)90379-0
Source DB: PubMed Journal: J Chromatogr