| Literature DB >> 31313522 |
Ria M Abdilla-Santes1,2, Wenze Guo1, Pieter C A Bruijnincx3,4, Jun Yue1, Peter J Deuss1, Hero J Heeres1.
Abstract
5-Hydroxymethylfurfural (HMF) is an important biobased platform chemical obtainable in high selectivity by the hydrolysis of fructose (FRC). However, FRC is expensive, making the production of HMF at a competitive market price highly challenging. Here, it is shown that sugar beet thick juice, a crude, sucrose-rich intermediate in sugar refining, is an excellent feedstock for HMF synthesis. Unprecedented high selectivities and yields of >90 % for HMF were achieved in a biphasic reactor setup at 150 °C using salted diluted thick juice with H2 SO4 as catalyst and 2-methyltetrahydrofuran as a bioderived extraction solvent. The conversion of glucose, obtained by sucrose inversion, could be limited to <10 mol %, allowing its recovery for further use. Interestingly, purified sucrose led to significantly lower HMF selectivity and yields, showing advantages from both an economic and chemical selectivity perspective. This opens new avenues for more cost-effective HMF production.Entities:
Keywords: 5-hydroxymethylfurfural; biobased chemicals; microreactors; renewable resources; sucrose
Year: 2019 PMID: 31313522 PMCID: PMC6790971 DOI: 10.1002/cssc.201901115
Source DB: PubMed Journal: ChemSusChem ISSN: 1864-5631 Impact factor: 8.928
Figure 1Sugar beet thick juice‐based SUC to HMF and GLC strategy applied in this work.
Figure 2Schematic overview of the continuous slug‐flow microreactor setup used in this study to allow for efficient HMF and GLC synthesis from SUC contained in sugar beet thick juice.
Figure 3Concentration–time profile (left) and yield, selectivity, and carbon balance (right) of H2SO4‐catalyzed SUC hydrolysis in a biphasic system with MTHF as the extraction phase: a) thick juice without addition of salt (C SUC(equiv.),0=0.5 m, pHaqueous=0.7 at 25 °C), b) thick juice with added 0.3 g mL−1 NaCl (C SUC(equiv.),0=0.5 m, pHaqueous=0.7 at 25 °C), and c) pure SUC with added 0.3 g mL−1 NaCl (C SUC(equiv.),0=0.5 m, pHaqueous=0.7 at 25 °C). Reaction conditions: T=150 °C, aqueous/organic ratio: 1:4 v/v.
Figure 4Concentration–time profile (left) and yield, selectivity, and carbon balance (right) of a) thick juice and b) SUC hydrolysis in slug‐flow microreactor in a biphasic system with MTHF in the presence of NaCl (0.1 g mL−1) at different residence times obtained by adjusting the flow rate. Solid bar: HMF yield (FRC‐based); shaded bar: HMF selectivity (FRC‐based); circle: carbon balance. Reaction conditions: C SUC(equiv.),0=0.48 m, T=150 °C, aqueous/organic ratio 1:4 v/v, pHaqueous=1.2 (25 °C). Error bars represent average values from three separate experiments.
Comparison of data for thick juice to HMF reaction in batch and continuous setups.[a]
|
Entry |
Setup |
[min] |
pH |
[mg mL−1] |
[mol %] |
[mol %] |
|---|---|---|---|---|---|---|
|
1 |
batch |
15 |
1.6 |
– |
24.1 |
76.7 |
|
2 |
cont. |
15 |
1.6 |
– |
43.9 |
84.1 |
|
3 |
batch |
30 |
1.6 |
– |
51.2 |
81.7 |
|
4 |
cont. |
30 |
1.6 |
– |
65.8 |
87.4 |
|
5 |
batch |
20 |
0.7 |
0.3 |
99.2 |
95.7 |
|
6 |
cont. |
15 |
1.2 |
0.1 |
94.4 |
91.5 |
|
7 |
cont. |
20 |
1.2 |
0.1 |
97.7 |
93.6 |
[a] Reactions performed at T=150 °C, H2O/MTHF ratio: 1:4 v/v, H2SO4 as acid catalyst. [b] Batch/residence time. [c] Determined by HPLC. [d] Based on FRC conversion.
Selected examples of HMF yields and selectivities in biphasic liquid–liquid systems in batch and continuous setups with MIBK and MTHF extraction solvents.[a]
|
Entry |
Feed |
Setup |
Conditions |
|
|
Ref. |
|---|---|---|---|---|---|---|
|
1 |
FRC |
batch |
aqueous/MIBK 1:4, 150 °C, 30 min |
23 |
43.5 |
|
|
2 |
FRC |
batch |
aqueous/MIBK 1:4, 160 °C, 2 h |
96.8 |
76 |
|
|
3 |
FRC/GLC[b] |
cont. |
aqueous/MIBK 1:4, 140 °C, 2 h, 0.05 |
94.4 |
72 |
|
|
4 |
FRC |
batch |
aqueous/MIBK 1:4, 150 °C, 45 min, 100 g L−1 H3BO4, 50 g L−1 NaCl |
70 |
65.7 |
|
|
5 |
SUC |
batch |
aqueous/MIBK 1:4, 150 °C, 2 h, 100 g L−1 H3BO4, 50 g L−1 NaCl |
– |
70 |
|
|
6 |
FRC |
cont. |
aqueous/MIBK 1:3, 140 °C, 15 min, 0.25 |
– |
74[c] |
|
|
7 |
thick juice |
batch |
aqueous/MTHF 1:4, 150 °C, 20 min, pH 0.6, 0.3 g mL−1 NaCl |
99.2 |
95.7 |
this work |
|
8 |
thick juice |
cont. |
aqueous/MTHF 1:4, 150 °C, 20 min, pH 1.2, 0.1 g mL−1 NaCl |
97.7 |
93.6 |
this work |
[a] HMF selectivity shown in the table was calculated based on FRC. [b] 1:1 mixture. [c] Isolated yield.