Literature DB >> 31306589

A Randomized Controlled Trial of PEEK Versus Titanium Interference Screws for Anterior Cruciate Ligament Reconstruction With 2-Year Follow-up.

Sarah Shumborski1, Emma Heath1, Lucy J Salmon1, Justin P Roe1, James P Linklater2, Michael Facek1, Leo A Pinczewski1,3.   

Abstract

BACKGROUND: Graft fixation with interference screws for anterior cruciate ligament (ACL) reconstruction is a highly successful technique. Polyether ether ketone (PEEK) is a novel thermoplastic polymer with high biocompatibility and mechanical properties that mimic native bone, and it can be imaged on computed tomography or magnetic resonance imaging (MRI) without signal flare.
PURPOSE: To compare the clinical performance of ACL reconstruction with PEEK and titanium interference screws at 2 years and to evaluate a novel method of measuring tunnel volume. STUDY
DESIGN: Randomized controlled trial; Level of evidence, 1.
METHODS: A total of 133 patients underwent arthroscopic ACL reconstruction with 4-strand hamstring autografts and were randomized to have titanium or PEEK interference screws for femoral and tibial tunnel fixation. At 2 years, subjective Lysholm and International Knee Documentation Committee scores were assessed and clinical examination performed. At 12 months, MRI was performed to assess graft incorporation and cyst formation, and a novel technique was employed to measure tunnel volumes.
RESULTS: There were no significant differences in graft rerupture rate, contralateral ACL rupture rate, subjective outcomes, or objective outcomes. In the titanium and PEEK groups, MRI demonstrated high overall rates of graft integration (96%-100% and 90%-93%, respectively) and ligamentization (89% and 84%) and low rates of synovitis (22% and 10%) and cyst formation (0%-18% and 13%-15%). There was a higher proportion of patients with incomplete graft integration within the femoral tunnel in the PEEK group as compared with the titanium group (10% vs 0%, P = .03); however, the authors suggest that metal artifact precluded proper assessment of the graft in the titanium group by MRI. Tunnel volumes also appeared to be equivalent in the 2 groups and were measured with a novel technique that was highly reproducible in the PEEK group secondary to the absence of flare.
CONCLUSION: Two-year clinical analysis of PEEK interference screws for femoral and tibial fixation of ACL reconstructions showed equivalent clinical performance to titanium interference screws. Given the excellent mechanical characteristics, biological compatibility, and absence of metal artifact on MRI, PEEK has become our material of choice for interference screw fixation in ACL reconstruction.

Entities:  

Keywords:  anterior cruciate ligament reconstruction; interference screw; polyether ether ketone (PEEK); titanium

Mesh:

Substances:

Year:  2019        PMID: 31306589     DOI: 10.1177/0363546519861530

Source DB:  PubMed          Journal:  Am J Sports Med        ISSN: 0363-5465            Impact factor:   6.202


  2 in total

1.  Novel press-fit technique of patellar bone plug in anterior cruciate ligament reconstruction is comparable to interference screw fixation.

Authors:  Janosch Häberli; Maximilian Heilgemeir; Sebastian Valet; Ameet Aiyangar; Tom Overes; Philipp Henle; Stefan Eggli
Journal:  Arch Orthop Trauma Surg       Date:  2021-08-30       Impact factor: 2.928

Review 2.  Management of proximal biceps tendon pathology.

Authors:  Simon P Lalehzarian; Avinesh Agarwalla; Joseph N Liu
Journal:  World J Orthop       Date:  2022-01-18
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.