Literature DB >> 31306287

Clinical Outcomes of a New Asymmetric Intracorneal Ring Segment for the Treatment of Keratoconus.

Alfredo Vega-Estrada1,2, Elisabet Chorro1,2, Ashraf Sewelam3, Jorge L Alio1,2.   

Abstract

PURPOSE: To report visual, refractive, and corneal aberrations after implantation of a new asymmetric intracorneal ring segment (ICRS).
METHODS: This was a prospective, multicenter clinical study including 30 eyes of 26 patients with keratoconus. All cases were implanted with an ICRS, named the VISUMRING (VR), which had an arc length of 353 degrees and 2 asymmetric sections that can be customized in base width, length, and thickness. Ophthalmic evaluation included uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refraction, topography, and anterior corneal aberrations using the Sirius System (CSO, Firenze, Italy). Mean follow-up period was 14.7 ± 7.9 months.
RESULTS: Significant improvement of both UDVA and CDVA was observed after 1 year. UDVA improved from 0.08 ± 0.22 to 0.22 ± 0.16 and CDVA from 0.24 ± 0.29 to 0.43 ± 0.18 (P = 0.01). A significant reduction of more than 7 D in the spherical equivalent from -12.38 ± 3.77 D to -5.00 ± 3.26 D (P < 0.05) was noted 1 year after the procedure. In terms of higher-order aberrations, a slight reduction that was not statistically significant in the higher-order and coma-like aberrations was noted at 1 year from 4.32 and 3.82, to 4.12 and 3.55, respectively. Regarding complications, 5 of the 30 cases needed to have the VR explanted throughout the follow-up period due to severe corneal melting.
CONCLUSIONS: VR ICRS improves vision and refraction and induces major corneal flattening in patients with keratoconus. Further design enhancement is needed to increase the reduction of the asymmetric corneal aberrations and reduce the extrusion rate.

Entities:  

Year:  2019        PMID: 31306287     DOI: 10.1097/ICO.0000000000002062

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  3 in total

1.  Continuous Intracorneal Ring Implantation in Keratoconus: Efficacy, Predictive Factors, and Complications.

Authors:  David Thiwa; Stephan Johannes Linke; Albert Daxer; Johannes Steinberg
Journal:  Clin Ophthalmol       Date:  2022-09-17

2.  Asymmetric Thickness Intracorneal Ring Segments for Keratoconus.

Authors:  Pedro Manuel Baptista; João Heitor Marques; Miguel Mesquita Neves; Miguel Gomes; Luís Oliveira
Journal:  Clin Ophthalmol       Date:  2020-12-16

3.  Refractive changes of a new asymmetric intracorneal ring segment with variable thickness and base width: A 2D finite-element model.

Authors:  Gonzalo García de Oteyza; Juan Álvarez de Toledo; Rafael I Barraquer; Sabine Kling
Journal:  PLoS One       Date:  2021-09-15       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.