AIMS: To quantify inter-observer variation between all the intracranial stereotactic radiosurgery (SRS) providers in England in delineating the target volumes of four brain tumour cases.
MATERIALS AND METHODS: Twenty-two, cross-platform SRS providers in England were instructed during a national commissioning assessment to contour the gross tumour volume (GTV) of six brain metastases, one cavernous sinus meningioma, one vestibular schwannoma and one pituitary adenoma. An expert reference group provided feedback if submitted contours were considered to be outliers and those centres were instructed to resubmit their contours. All contours were analysed in Python. The target volume contour (observed volume; VOBS), encompassing volume, 50% agreement volume (AV50), 100% agreement volume (AV100), concordance index (CCI) and discordance index (DCI) were calculated.
RESULTS: Twenty-one centres participated using five different treatment platforms (CyberKnife, Gamma Knife, Varian Linac, Elekta Linac, Tomotherapy) and seven different treatment planning systems (GammaPlan, iPlan, Multiplan, Pinnacle, Eclipse, CMS Focal). The greatest variability was observed in the smallest brain metastases (GTV5 AV50 0.0 cm3, CCI 0.28-0.84, DCI 0.00-0.70) and pituitary case (AV50 1.1 cm3, CCI 0.42-0.82, DCI 0.01-0.40). The greatest agreement was observed with the vestibular schwannoma (AV50 2.8 cm3, CCI 0.77-0.94, DCI 0.00-0.17). There were four resubmissions for the cavernous sinus meningioma and three resubmissions for the pituitary adenoma.
CONCLUSIONS: Inter-observer variability was most evident with the smallest brain metastases and pituitary case. Several additional outliers and one acceptable contour were suggested using the metric-based analysis of AV50, CCI and DCI. Comparing contours using these metrics is an effective way to identify whether individual contours are similar to the 'true' target and to flag potentially significant deviations.
Copyright © 2019. Published by Elsevier Ltd.

Entities:  

Keywords:  Brain metastases; contouring; meningioma; pituitary adenoma; stereotactic radiosurgery; vestibular schwannoma

Year:  2019        PMID: 31301960     DOI: 10.1016/j.clon.2019.06.015

Source DB:  PubMed          Journal:  Clin Oncol (R Coll Radiol)        ISSN: 0936-6555            Impact factor:   4.126


  5 in total

1.  Development and Practical Implementation of a Deep Learning-Based Pipeline for Automated Pre- and Postoperative Glioma Segmentation.

Authors:  E Lotan; B Zhang; S Dogra; W D Wang; D Carbone; G Fatterpekar; E K Oermann; Y W Lui
Journal:  AJNR Am J Neuroradiol       Date:  2021-12-02       Impact factor: 3.825

2.  Deep learning-based detection and segmentation-assisted management of brain metastases.

Authors:  Jie Xue; Bao Wang; Yang Ming; Xuejun Liu; Zekun Jiang; Chengwei Wang; Xiyu Liu; Ligang Chen; Jianhua Qu; Shangchen Xu; Xuqun Tang; Ying Mao; Yingchao Liu; Dengwang Li
Journal:  Neuro Oncol       Date:  2020-04-15       Impact factor: 12.300

3.  Opportunities for integration of artificial intelligence into stereotactic radiosurgery practice.

Authors:  Rupesh Kotecha; Sanjay Aneja
Journal:  Neuro Oncol       Date:  2021-10-01       Impact factor: 13.029

4.  Inter-clinician delineation variation for a new highly-conformal flank target volume in children with renal tumors: A SIOP-Renal Tumor Study Group international multicenter exercise.

Authors:  Joeri Mul; Patrick Melchior; Enrica Seravalli; Daniel Saunders; Stephanie Bolle; Alison L Cameron; Kristin Gurtner; Semi Harrabi; Yasmin Lassen-Ramshad; Naomi Lavan; Henriette Magelssen; Henry Mandeville; Tom Boterberg; Petra S Kroon; Alexis N T J Kotte; Bianca A W Hoeben; Peter S N van Rossum; Martine van Grotel; Norbert Graf; Marry M van den Heuvel-Eibrink; Christian Rübe; Geert O Janssens
Journal:  Clin Transl Radiat Oncol       Date:  2021-03-11

5.  Target localization accuracy in frame-based stereotactic radiosurgery: Comparison between MR-only and MR/CT co-registration approaches.

Authors:  Eleftherios P Pappas; Ioannis Seimenis; Panagiotis Kouris; Stefanos Theocharis; Kostas I Lampropoulos; Georgios Kollias; Pantelis Karaiskos
Journal:  J Appl Clin Med Phys       Date:  2022-03-14       Impact factor: 2.243

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.