Literature DB >> 31301439

Diverse Use of the WEB Device: A Technical Note on WEB Stenting and WEB Coiling of Complex Aneurysms.

Mario Zanaty1, Jorge A Roa2, Sudeepta Dandapat3, Edgar A Samaniego4, Pascal Jabbour5, David Hasan6.   

Abstract

The Woven EndoBridge (WEB) device, an intrasaccular flow-diverter that does not require long-term antiplatelet use, has recently emerged as an alternative to embolize complex intracranial aneurysms; however, there are limitations to the WEB device. First, it does not immediately secure the aneurysm in most subarachnoid hemorrhage cases. Second, it may not be suitable for embolization of wide-neck aneurysms with an unfavorable aspect ratio. To overcome these limitations, we have used the WEB device in conjunction with stenting and/or coiling. Here, we present a technical note with an illustrated case series and provide a detailed step-by-step description on how the WEB device can be used in adjunct to coiling and/or stenting to achieve successful angiographic results. Accurate sizing of the WEB device before deployment is critical. Larger case series are required to further assess the safety and success of these combined techniques.
Copyright © 2019 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Coiling; Embolization; Flow-diversion; Intracranial aneurysm; Stenting; WEB device; Wide-neck

Mesh:

Year:  2019        PMID: 31301439     DOI: 10.1016/j.wneu.2019.07.027

Source DB:  PubMed          Journal:  World Neurosurg        ISSN: 1878-8750            Impact factor:   2.104


  4 in total

1.  Off-Label Use of the WEB Device.

Authors:  Mario Zanaty; Jorge A Roa; Stavropoula I Tjoumakaris; Pascal Jabbour; Nikolaos Mouchtouris; Ahmad Sweid; Santiago Ortega-Gutierrez; Daizo Ishii; Kaustubh Limaye; Khaled Asi; Edgar A Samaniego; David M Hasan
Journal:  World Neurosurg       Date:  2019-11-20       Impact factor: 2.104

2.  Safety and feasibility of the Woven EndoBridge device deployment with monitored anesthesia care.

Authors:  Daizo Ishii; Luyuan Li; Mario Zanaty; Jorge A Roa; Lauren Allan; Edgar A Samaniego; David M Hasan
Journal:  Interv Neuroradiol       Date:  2020-06-17       Impact factor: 1.610

3.  Volume-based sizing of the Woven EndoBridge (WEB) device: A preliminary assessment of a novel method for device size selection.

Authors:  Kevin A Shah; Timothy G White; Ina Teron; Thomas Link; Amir R Dehdashti; Jeffrey M Katz; Henry H Woo
Journal:  Interv Neuroradiol       Date:  2021-01-21       Impact factor: 1.764

4.  Technical aspects of combined intrasaccular and endoluminal flow diversion.

Authors:  Timothy G White; Kevin Shah; Justin Turpin; Thomas Link; Amir R Dehdashti; Jeffrey M Katz; Henry H Woo
Journal:  Interv Neuroradiol       Date:  2020-11-29       Impact factor: 1.764

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.