| Literature DB >> 31299927 |
Xiang Zhou1, Chao Ma2, Zhi Wang1, Jia-Ling Liu1, Yuan-Peng Rui1, Yue-Hua Li3, Yi-Feng Peng4.
Abstract
BACKGROUND: To determine the effect of region of interest (ROI) on tumor's apparent diffusion coefficient (ADC) and interobserver variability in thyroid nodules.Entities:
Keywords: ADC; DWI; MRI; Region of interest; Thyroid nodule
Mesh:
Year: 2019 PMID: 31299927 PMCID: PMC6625060 DOI: 10.1186/s12880-019-0357-x
Source DB: PubMed Journal: BMC Med Imaging ISSN: 1471-2342 Impact factor: 1.930
Histopathological types of thyroid nodules in the evaluated patients
| Pathological classification | Number of nodules | Number of cases | Age | |
|---|---|---|---|---|
| Range | Average | |||
| Papillary carcinoma | 14 | 12 | 37~64 | 51.5 |
| Follicular carcinoma | 1 | 1 | 28~28 | 28.0 |
| Adenoma | 20 | 11 | 25~63 | 51.6 |
| Nodular goiter | 15 | 9 | 43~71 | 56.4 |
Main scan parameters and sequences for thyroid gland evaluation
| MR Imaging Sequence | TR (ms) | TE (ms) | FOV (mm2) | Matrix | Slice Thickness(mm) | Spacing (mm) | NEX | Number of Slices |
|---|---|---|---|---|---|---|---|---|
| Axial T1WI | 520 | 14 | 200 × 200 | 320 × 192 | 4 | 0.5 | 3 | 12~14 |
| Axial T2WI | 3500 | 102 | 200 × 200 | 320 × 224 | 4 | 0.5 | 4 | 12~14 |
| Coronal T1WI | 550 | 11.1 | 240 × 240 | 320 × 224 | 3 | 0.5 | 4 | 12~14 |
| Coronal T2WI | 3000 | 102 | 240 × 240 | 320 × 224 | 3 | 0.5 | 4 | 12~14 |
| Axial DWI (b = 0, 400 s/mm2) | 6000 | 60.1 | 200 × 200 | 128 × 128 | 4 | 0.5 | 4 | 12~14 |
Fig. 1Images obtained from a 28-year-old female patient with histologically proven follicular thyroid carcinoma in the left lobe. In the whole-volume (c-j) and single-slice (g) methods, freehand ROIs were drawn along the high signal intensity border of the tumor to cover the entire tumor on DWI at b400. In the solid sample method, three circular ROIs were placed within the tumor areas of the highest cellular activity on DWI at b400. The tumor areas showed high signals on DWI at b400 and low signals on the ADC map (k). a, Axial T2WI; b, Axial T1WI; c-j, DWI (b400); K, ADC map
Inter-observer comparison of apparent diffusion coefficient (ADC) values (× 10− 3 mm2/s) for benign thyroid nodules obtained by the whole-volume, single-slice and solid-sample ROI methods by two independent readers
| Parameters | Solid-sample ROI | Single-slice ROI | Whole-volume ROI | |||
|---|---|---|---|---|---|---|
| Reader 1 | Reader 2 | Reader 1 | Reader 2 | Reader 1 | Reader 2 | |
| ADC400 | 2.03 (1.88, 2.27) [1.48, 2.93] | 2.02 (1.96, 2.20) [1.67, 2.95] | 2.03 (1.91, 2.36) [1.73, 3.17] | 2.06 (1.93, 2.18) [1.65, 3.24] | 2.05 (1.94, 2.28) [1.80, 3.25] | 2.06 (1.92, 2.19) [1.73, 3.26] |
*Data are expressed as median; numbers in parentheses are first (q1) and third (q3) quartiles; numbers in brackets are ranges
Inter-observer comparisons of apparent diffusion coefficient (ADC) values (× 10− 3 mm2/s) for malignant thyroid nodules obtained by the whole-volume, single-slice and solid-sample ROI methods by two independent readers
| Parameters | Solid-sample ROI | Single-slice ROI | Whole-volume ROI | |||
|---|---|---|---|---|---|---|
| Reader 1 | Reader 2 | Reader 1 | Reader 2 | Reader 1 | Reader 2 | |
| ADC400 | 1.67 (1.47, 1.79) [1.00, 2.01] | 1.63 (1.53, 1.88) [1.22, 2.01] | 1.84 (1.65, 1.90) [1.25, 2.07] | 1.74 (1.63, 1.87) [1.35, 2.15] | 1.70 (1.57, 1.81) [1.23, 1.96] | 1.78 (1.61, 1.85) [1.33, 2.04] |
*Data are expressed as median; numbers in parentheses are first (q1) and third (q3) quartiles; numbers in brackets are ranges
Fig. 2Interobserver reproducibility of mean ADC measurements (×10−3 mm2/s) for all three ROI methods in benign thyroid nodules. In Bland-Altman plots, the differences in mean ADC measurements (y-axis) were plotted against the mean ADCs (x-axis). Continuous line, mean absolute difference (bias); dashed line, 95% confidence interval of the mean difference (limits of agreement)
Fig. 3Interobserver reproducibility of mean ADC measurements (× 10− 3 mm2/s) for all three ROI methods in malignant thyroid nodules. In Bland-Altman plots, the differences in mean ADC measurements (y-axis) were plotted against the mean ADCs (x-axis). Continuous line, mean absolute difference (bias); dashed line, 95% confidence interval of the mean difference (limits of agreement)
Comparisons of mean ADC400 (× 10− 3 mm2/s) (± standard deviation, SD) measured by the whole-volume, single-slice and solid-sample methods for noncancerous and cancerous thyroid nodules
| Category | Solid-sample ROI | Single-slice ROI | Whole-volume ROI |
|
|---|---|---|---|---|
| Noncancerous thyroid nodules | 2.12 ± 0.32 | 2.15 ± 0.35 | 2.14 ± 0.34 |
|
| Cancerous thyroid nodules | 1.65 ± 0.22 | 1.74 ± 0.21 | 1.70 ± 0.19 |
|
Fig. 4Mean ADC (× 10− 3 mm2/s) measured by the whole-volume, single-slice and solid-sample methods for noncancerous and cancerous thyroid nodules
Fig. 5ROC curves of ADC values measured by the whole-volume, single-slice and solid-sample methods for benign and malignant thyroid nodules
ROC analyses of ADC measured by the whole volume, single slice and small solid-sample methods for benign and malignant thyroid nodules
| Category | Small solid-sample ROI | Single-slice ROI | Whole-volume ROI |
|---|---|---|---|
| AUC | 0.891 | 0.870 | 0.934 |
| Cut-off value (×10−3 mm2/s) | 1.90 | 1.90 | 1.84 |
| Sensitivity | 83.3% | 83.3% | 80.0% |
| Specificity | 80.0% | 78.3% | 88.3% |
| Youden Index | 0.616 | 0.600 | 0.683 |