Literature DB >> 31298758

A New Quantum Cascade IR-Laser Online Detector: Chemical-Sensitive Size-Exclusion Chromatography Measurement at Unprecedented Low Levels.

Jennifer M Kübel1, Carlo Botha1, Aleksandra Bucka1, Johannes Höpfner1, Henrik Zimmermann2, Matthias Godejohann3, Manfred Wilhelm1.   

Abstract

Online chemically sensitive detectors for size exclusion chromatography (SEC) through coupled setups based on infrared (IR) (or NMR) spectrometers present new possibilities through unprecedented levels of polymer detail with respect to molecular weight and chemical composition. Herein, a new external cavity quantum cascade laser (EC-QCL) mid-IR spectrometer as a chemically sensitive online detector for SEC is custom-designed, built, and tested. This unique spectrometer features multiple broadly tunable EC-QCL sources, which can be operated in continuous wave and pulsed mode, accompanied with balanced liquid nitrogen cooled mercury cadmium telluride (MCT) detectors and a new custom-built transmission flow cell. Automated data analysis is done with a self-written MATLAB code. The limit of detection (LOD) is measured online, coupled with SEC chromatography, where on average, one carbonyl functionality in 530 000 g mol-1 at chromatographic conditions for SEC could be detected. It is possible to detect 0.46 µg (LOD) PMMA, which is approximately a factor of 30 lower than that reported for SEC-Fourier transform infrared.
© 2019 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Keywords:  hyphenated techniques; quantum cascade lasers; size exclusion chromatography

Mesh:

Substances:

Year:  2019        PMID: 31298758     DOI: 10.1002/marc.201900228

Source DB:  PubMed          Journal:  Macromol Rapid Commun        ISSN: 1022-1336            Impact factor:   5.734


  2 in total

1.  The Next Generation of IR Spectroscopy: EC-QCL-Based Mid-IR Transmission Spectroscopy of Proteins with Balanced Detection.

Authors:  Christopher K Akhgar; Georg Ramer; Mateusz Żbik; Artur Trajnerowicz; Jarosław Pawluczyk; Andreas Schwaighofer; Bernhard Lendl
Journal:  Anal Chem       Date:  2020-07-13       Impact factor: 6.986

2.  Polarimetric Balanced Detection: Background-Free Mid-IR Evanescent Field Laser Spectroscopy for Low-Noise, Long-term Stable Chemical Sensing.

Authors:  Stephan Freitag; Matthias Baer; Laura Buntzoll; Georg Ramer; Andreas Schwaighofer; Bernhard Schmauss; Bernhard Lendl
Journal:  ACS Sens       Date:  2020-12-29       Impact factor: 7.711

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.