Radiotherapy of the resected mandible following stainless steel plate fixation.

N Scher1, D Poe, F Kuchnir, C Reft, R Weichselbaum, W R Panje.   

Abstract

There is general concern among otolaryngologists that irradiation of a stainless steel prosthesis used in mandibular reconstruction may cause irradiation overdosage to adjacent tissues. A tissue-equivalent plastic/steel model, simulating the characteristics of a stainless steel, reconstructed mandible, was irradiated and measurements were made with a parallel plate ionization chamber. The results of our measurements show that irradiation of an implanted steel plate results in an overdosage (120%) "in front" and an underdosage (80%) "behind" the steel plate. The regions of overdosage and underdosage are 2 to 3 mm thick. The overall dose modification is greatly reduced when two opposing fields are used. We conclude that irradiation of a stainless steel, reconstructed mandible with a 6-mV photon beam through opposing fields does not significantly alter the amount of radiation delivered to surrounding tissues.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3129630     DOI: 10.1288/00005537-198805000-00017

Source DB:  PubMed          Journal:  Laryngoscope        ISSN: 0023-852X            Impact factor:   3.325


  7 in total

1.  Will the hold of solid biodegradable implants be influenced by swelling during the degradation process? An in-vitro study with Meniscus Arrows.

Authors:  Diederick B Wouters; Rudolf R M Bos; Jeff T De Hosson
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2007-06-23       Impact factor: 4.342

2.  Efficacy of bioresorbable plates in the osteosynthesis of linear mandibular fractures.

Authors:  Satyavrat Arya; Krushna Bhatt; Ongkila Bhutia; Ajoy Roychoudhury
Journal:  Natl J Maxillofac Surg       Date:  2020-06-18

3.  Fixation of osteochondral fragments in the human knee using Meniscus Arrows.

Authors:  Diederick B Wouters; Johannes G M Burgerhof; Jeff T M de Hosson; Rudolf R M Bos
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-05-13       Impact factor: 4.342

4.  Estimation of dose enhancement to soft tissue due to backscatter radiation near metal interfaces during head and neck radiothearpy - A phantom dosimetric study with radiochromic film.

Authors:  Rajesh Ashok Kinhikar; Chandrashekhar M Tambe; Kalpana Patil; Mahadev Mandavkar; Deepak D Deshpande; Rajendra Gujjalanavar; Prabha Yadav; Ashwini Budrukkar
Journal:  J Med Phys       Date:  2014-01

5.  Study of dosimetric properties of flattened and unflattened megavoltage x ray beam on high Z implant materials.

Authors:  Tamilarasan Rajamanickam; Sivakumar Muthu; Perumal Murugan; Muddappa Pathokonda; Krishnamoorthy Senthilnathan; Narayanasamy Arunai Nambi Raj; Padmanabhan Ramesh Babu
Journal:  J Appl Clin Med Phys       Date:  2018-09-28       Impact factor: 2.102

Review 6.  Preparation Methods for Improving PEEK's Bioactivity for Orthopedic and Dental Application: A Review.

Authors:  Davood Almasi; Nida Iqbal; Maliheh Sadeghi; Izman Sudin; Mohammed Rafiq Abdul Kadir; Tunku Kamarul
Journal:  Int J Biomater       Date:  2016-04-04

7.  Monte Carlo simulation and film dosimetry for electron therapy in vicinity of a titanium mesh.

Authors:  Keyvan Jabbari; Masoumeh Rostampour; Mahnaz Roayaei
Journal:  J Appl Clin Med Phys       Date:  2014-07-08       Impact factor: 2.102

  7 in total