Literature DB >> 31293262

The evaluation of microleakage and fluoride release of different types of glass ionomer cements.

E Bahsi1, S Sagmak1, B Dayi2, O Cellik3, Z Akkus4.   

Abstract

BACKGROUND: The aim of this study was to evaluate six different glass ionomer cement (GIC)-based restorative materials through comparisons of microleakage and fluoride release.
MATERIALS AND METHODS: For microleakage, 30 teeth were randomly separated into 6 groups of 5: Group 1 (Dyract: compomer), Group 2 (Freedom: compomer), Group 3 (Equia: high-viscosity glass ionomer cements), Group 4 (Fuji IX: resin-modified glass ionomer cement), Group 5 (Ketac Molar: traditional glass ionomer cement [TGIC]) and Group 6 (Voco: TGIC). For fluoride release of six different GIC-based restorative materials, standard samples were prepared of 4 mm thickness and 7 mm diameter. A total of 60 samples were obtained as 10 samples from each group. The analyses were made using a Thermo Orion 720 A+ ionometer with the Orion fluoride electrode. At the end of 24 h, 72 h, 7 days, 14 days, and 30 days, the electrode was placed into the dish containing the sample, distilled water, and TISAB II; a reading was taken; and the value shown on the screen was recorded.
RESULTS: For microleakage, a statistically significant difference was determined between the groups in respect of the occlusal variable (P < 0.05), no statistically significant gingival variable (P > 0.05). About fluoride release: According to the repeated measures variance analysis results, the difference between the groups, and between the time-group interaction and according to time, was found to be statistically significant (P < 0.05).
CONCLUSIONS: In terms of microleakage, it was concluded that all materials could be used in clinical applications. The Equia high-viscosity glass ionomer cements (HVGIC) was determined to be the material with the highest fluoride release value.

Entities:  

Keywords:  Fluoride release; glass ionomer cement; microleakage

Mesh:

Substances:

Year:  2019        PMID: 31293262     DOI: 10.4103/njcp.njcp_644_18

Source DB:  PubMed          Journal:  Niger J Clin Pract            Impact factor:   0.968


  5 in total

1.  Comparison of physical and mechanical properties of three different restorative materials in primary teeth: an in vitro study.

Authors:  B Keskus; F Oznurhan
Journal:  Eur Arch Paediatr Dent       Date:  2022-07-21

2.  Effect of the Addition of Varying Concentrations of Silver Nanoparticles on the Fluoride Uptake and Recharge of Glass Ionomer Cement.

Authors:  Turki D Alshehri; Sunil Babu Kotha; Faisal Mohammed Abed; Mohammed J Barry; Abdulrahman AlAsmari; Sreekanth Kumar Mallineni
Journal:  Nanomaterials (Basel)       Date:  2022-06-08       Impact factor: 5.719

3.  Effect of Saliva Contamination on Microleakage of Open Sandwich Restorations.

Authors:  Çiğdem Çelik; Yusuf Bayraktar; Behiye Esra Özdemir
Journal:  Acta Stomatol Croat       Date:  2020-09

4.  Fluoride release from two types of fluoride-containing orthodontic adhesives: Conventional versus resin-modified glass ionomer cements-An in vitro study.

Authors:  Yasemin Dziuk; Sachin Chhatwani; Stephan C Möhlhenrich; Sabrina Tulka; Ella A Naumova; Gholamreza Danesh
Journal:  PLoS One       Date:  2021-02-26       Impact factor: 3.240

5.  A comparative evaluation of microleakage and dentin shear bond strength of three restorative materials.

Authors:  Alpana Kumari; Namita Singh
Journal:  Biomater Investig Dent       Date:  2022-02-10
  5 in total