Literature DB >> 31292613

Isolated aortic insufficiency valve repair with external ring annuloplasty: a standardized approach.

Mustafa Zakkar1,2, Vito D Bruno3, Pavel Zacek4, Isabelle Di Centa5, Christophe Acar1, Nizar Khelil1, Mathieu Debauchez1, Emmanuel Lansac1.   

Abstract

OBJECTIVES: Aortic valve (AV) insufficiency with normal root and ascending aorta is most frequently treated by valve replacement with significant prosthetic-related complications and reduced life expectancy. We compared the outcomes of a new standardized isolated AV repair approach using an external aortic annuloplasty ring at the subvalvular level (single ring annuloplasty) and the role of an additional supravalvular ring at the sinotubular junction (double ring annuloplasty).
METHODS: Single centre data were collected from the Aortic Valve Insufficiency and ascending aorta Aneurysm InternATiOnal Registry (AVIATOR) between 2003 and 2017. A total of 93 patients (56 single ring and 37 double ring) underwent isolated AV repair.
RESULTS: The overall 30-day mortality rate and the need for a permanent pacemaker were 1% and 2%, respectively. The overall survival rate at 6 years was similar for sex- and age-matched members of the general population (89% vs 95%; P = 0.1) and did not differ between the double and single ring groups (82% vs 93%; P = 0.4) at 6 years. There were no thromboembolic or bleeding events in the entire cohort. However, at 6 years, the cumulative incidence of valve-related reintervention was 26% in the single ring annuloplasty group compared to 3% in the double ring annuloplasty (P = 0.02) group. Similarly, at 6 years, the cumulative incidence of moderate-to-severe (>2) aortic insufficiency was 30% in the single ring annuloplasty group compared to 0% in the double ring annuloplasty group (P = 0.007).
CONCLUSIONS: Standardized AV repair with external ring annuloplasty has a survival rate similar to that of the general population. The additional stabilization of the sinotubular junction with a second supravalvular ring (double ring annuloplasty) is associated with better outcomes compared to single subvalvular annuloplasty. It can be considered as a first line intervention for patients with isolated aortic insufficiency and pliable leaflets.
© The Author(s) 2019. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

Entities:  

Keywords:  Aortic insufficiency; Bicuspid; External ring annuloplasty; Valve repair

Mesh:

Year:  2020        PMID: 31292613     DOI: 10.1093/ejcts/ezz193

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  4 in total

1.  Early results after aortic annuloplasty with a complete external Dacron band.

Authors:  John-Peder Escobar Kvitting; Jan Otto Beitnes; Runar Lundblad
Journal:  Gen Thorac Cardiovasc Surg       Date:  2021-09-20

2.  Management of anomalous coronary anatomy during aortic valve repair.

Authors:  Piroze M Davierwala; Imran Khan; Christian Etz; Michael A Borger
Journal:  Ann Cardiothorac Surg       Date:  2022-07

3.  Comparison of bicuspidization and Ross procedure in the treatment of unicuspid aortic valve disease in adults - Insight from the AVIATOR registry.

Authors:  Ján Gofus; Mikita Karalko; Petr Fila; Jiří Ondrášek; Hans-Joachim Schäfers; Adrian Kolesár; Emmanuel Lansac; Ismail El-Hamamsy; Laurent de Kerchove; Christian Dinges; Jaroslav Hlubocký; Petr Němec; Martin Tuna; Jan Vojáček
Journal:  Front Cardiovasc Med       Date:  2022-09-08

4.  Aortic annuloplasty: Subcommissural, intra-annular suture techniques, external and internal rings.

Authors:  Jan M Federspiel; Tristan Ehrlich; Karen Abeln; Hans-Joachim Schäfers
Journal:  JTCVS Tech       Date:  2021-01-28
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.