Clinical comparison of speculum's influence on intraoperative aberrometry reading.

Rodrigo Franco Lafetá Queiroz1,2, Danilo Varela Kniggendorf1,2, André Lins de Medeiros1,2, Wilson Takashi Hida1,2,3,4, Celso Takashi Nakano1,2, Pedro Carlos Carricondo3, Walton Nosé4, Andre Gustavo Rolim1,2, Antonio Francisco Pimenta Motta1,2.   

Abstract

PURPOSE: The aim of this study was to evaluate the influence of four different types of speculums on aberrometry reading (OPD SCAN III [OPD]) and on intraoperative aberrometry reading (optiwave response analyzer, ORA). PATIENTS AND METHODS: This prospective, controlled, comparative study of consecutive cases included the evaluation of five eyes of five patients with monofocal intraocular lens (IOL) implantation. Seventeen measures were performed on each patient: for each speculum, there were two measurements on the OPD and another two on ORA with four different types of blepharostats. A control measure was performed on the without blepharostat in the dominant eye of each patient, therefore totalizing 85 measurements. The measures with the blepharostats were as follows: without pressure (WF) or passive measure and after pressure (AF) or active measure to close the eye. The speculum used in all patients was as follows: open-edged wire (Barraquer); threaded with open blade (Lieberman), with 21 mm aperture; wired with solid blade (Barraquer); and threaded with solid blade (Lieberman) with 21 mm opening. An evaluation of the objective refractive data from the OPD and ORA and the corneal astigmatism from the OPD was performed.
RESULTS: Spherical equivalent (SE) of the OPD with the use of blepharostat compared to the OPD without speculum presented only 37.5% of results without statistical significance. Regarding the SE of ORA with speculum usage, compared to the OPD without blepharostat, only 12.5% were not significant. Regarding the accuracy of the ORA refractive axis with the use of blepharostats, all results presented statistical significance.
CONCLUSION: Thus, in the present study, we reached the conclusion between the studied blepharostats that the most suitable for use in the aphakic and pseudophakic capture of the ORA is the open blade threaded blepharostat (Lieberman).

Entities:  

Keywords:  astigmatism; cataract; cornea; corneal topography; surgery

Year:  2019        PMID: 31289436      PMCID: PMC6560926          DOI: 10.2147/OPTH.S177992

Source DB:  PubMed          Journal:  Clin Ophthalmol        ISSN: 1177-5467


Introduction

Cataract surgery became increasingly safer and more reproducible over the recent years with the introduction of modern techniques of phacoemulsification and with the evolving technology combined with the introduction of femtosecond laser and anti-surge mechanisms, being the most performed surgery in the world.1 The opening of the eyelid for ocular surgery used to be a complex problem. Three procedures were suggested for the solution of this problem, involving the use of the following: retractors (insured by an assistant), blepharostats (speculum), sutures (inserted into the free eyelid border or skin or held in place by means of metallic devices).2 Along with an increasingly early diagnosis, there is currently a greater demand among patients who want to maintain their productivity and daily activities.3 A postoperative outcome without refractive errors is one of the main objectives of modern phacoemulsification. The corneal topography has been the most used examination to guide the surgical plane and to evaluate the postoperative results. Nevertheless, real-time information about the refractive state during cataract surgery can assist in the correct placement of intraocular lenses (IOLs), and it may also automatically consider the induced astigmatism in clear corneal incisions.4 Wavefront aberrometry is widely used to improve outcomes after visual laser correction. However, the types of aberrometers used in keratorefractive surgeries are too large to be used intraoperatively, and their variation and dynamic range are not wide enough for the aphakic measures required for cataract surgery. The optiwave response analyzer (ORA; Alcon Inc, Fort Worth, TX, USA) is small enough to be mounted under the surgical microscope and is fully integrated into an easy and accessible interface for the surgeon; it is the third-generation version of the intraoperative aberrometry system.5–7 OPD-SCAN III ([OPD]; Nidek, Gamagori, Japan) is an aberrometer popularly used in the preoperative period of cataract surgery for surgical incision programming and astigmatism correction.8 Therefore, it requires a blepharostat that induces the least refractive error to calculate the IOL to be implanted. The purpose of this study was to evaluate the influence of four different types of blepharostats on aberrometry reading (OPD) and on intraoperative aberrometry reading (ORA) in order to know whether there is a significant difference between them.

Patients and methods

This prospective, controlled, comparative study of consecutive cases included the evaluation of five eyes of five patients submitted to femtosecond laser cataract surgery with monofocal IOL implantation. Four measures were performed with each blepharostat: two on the OPD and another two on ORA (intraoperative aberrometer) with four different types of blepharostats. A control measure was performed on the OPD, aberrometer, without speculum in the dominant eye of each patient. Therefore, despite a small number of subjects, we could reach a total amount of 85 measurements in this paper. The measures with the blepharostats were as follows: without force (WF) or passive measure and after forcing (AF) or active measure to close the eye. The speculum used in all cases was as follows: open-edged wire – Barraquer (speculum Barraquer odous with open blade [B1]; Odous, Belo Horizonte, Brazil; Figure 1); threaded with open blade – Lieberman forceps (speculum Lieberman forceps with open blade [B2]; Katena, Denville, NJ, USA), with 21 mm aperture (Figure 2); wired with solid blade – Barraquer (speculum Barraquer odous with closed blade [B3]; Odous; Figure 3); and threaded with solid blade – Lieberman (speculum Lieberman odous with closed blade [B4]; Odous; Figure 4) with 21 mm opening; all were made from the same material.
Figure 1

B1 – speculum Barraquer odous with open blade.

Figure 2

B2 – speculum Lieberman forceps with open blade.

Figure 3

B3 – speculum Barraquer odous with closed blade.

Figure 4

B4 – speculum Lieberman odous with closed blade.

An evaluation of the objective (spherical, cylinder, and axis) refractive data from the OPD and ORA and the corneal astigmatism (flat axis value [K1], steep axis value [K2], and respective axis) from the OPD was performed. Spherical equivalent (SE) was the primary outcome measure. Inclusion criteria were as follows: age between 50 and 75 years, axial length between 22.5 and 24.5 mm, femtosecond laser-assisted cataract surgery, absence of posterior capsule opacity, corneal thickness between 500 and 580 μm. Exclusion criteria were as follows: ocular pathologies, irido-corneal angle <25°, eyelid drooping. Statistical significance was tested using Student’s t-test and p-value for the analysis of the data collected. To infer the conclusion about which would be the best blepharostat, an absolute numerical methodology was applied, using a summary of significant p-values for each variable and apparatus (Table 1) and a table of means for each variable and apparatus (Table 2). Then, a ranking of the points of the lowest variations was performed when compared to the examination without speculum. After that, a numerical result was verified for each variable, being excluded from the ranking when the values were statistically significant (Table 3). In this way, we took the sum of the ranking for each variable and multiplied by the number of times it was statistically significant, thus obtaining a general ranking where the lowest value equals the best blepharostat (Table 4).
Table 1

p-values (Student’s t-test)

SpeculumSR OPDCR OPDAxis of ast. refraction OPDSE refraction OPDValue of K1 OPDAxis of K1 OPDValue of K2 OPDAxis of K2 OPDValue of ast. OPDSR ORACR ORAAxis of ast. refraction ORASE refraction ORA
B1AF0.23020.17700.06800.10110.04800.15920.00420.14150.05860.00780.00950.00010.0451
B1WF0.01860.12020.00730.03000.04760.15150.08560.12620.11980.03930.06110.00030.0167
B2AF0.04020.22720.04030.00090.02900.23260.14770.01550.15410.03150.11950.00000.0020
B2WF0.09930.05140.12220.01840.01350.32600.05740.10550.10120.05250.00050.00030.0147
B3AF0.00700.00580.13880.03400.05780.11830.00450.05730.01810.05570.00110.00050.0845
B3WF0.01380.02440.14510.13170.08740.06530.02010.14600.01490.00160.01860.00070.0008
B4AF0.03670.07210.17970.01660.13650.08690.10510.08100.07380.01360.01130.00050.0388
B4WF0.29680.11290.04480.14890.02690.19110.06280.23060.08790.07050.00940.00110.0220

Notes: B1, speculum Barraquer odous with open blade; B2, speculum Liebermann forceps with open blade; B3, speculum Barraquer odous with closed blade; B4, speculum Lieberman odous with closed blade.

Abbreviations: AF, after pressure; ast., astigmatism; CR, cylindrical refraction; K1, steepest keratometric reading; K2, flattest keratometric reading; OPD, OPD-SCAN III; ORA, optiwave response analyzer; SE, spherical equivalent; SR, spherical refraction; WF, without pressure.

Table 2

Mean absolute distances per appliance and variable

SpeculumSR OPDCR OPDAxis of ast. refraction OPDSE refraction OPDValue of K1 OPDAxis of K1 OPDValue of K2 OPDAxis of K2 OPDValue of ast. OPDSR ORACR ORAAxis of ast. refraction ORASE refraction ORA
B1AF1.25001.650065.60000.77400.408033.80000.704052.20000.62800.20800.466090.80000.3220
B1WF0.65000.4000104.40000.59600.420050.80000.676060.80000.91200.42801.024088.00000.3500
B2AF0.55000.400024.60000.40000.648040.40000.614014.40000.67400.81801.056085.20000.3320
B2WF0.40000.550058.20000.22600.740035.20000.54606.80000.80600.41601.1780125.00000.2600
B3AF1.30002.250032.00000.77001.412030.80001.332088.40002.74400.49400.8540110.20000.4640
B3WF1.35001.100033.40000.99600.766011.40000.850068.60001.28001.04800.726092.80000.9960
B4AF0.45000.850035.00001.02202.876062.60001.430037.00002.76600.34601.1340123.40000.5280
B4WF2.60003.500052.60002.14800.836046.80000.338031.60000.83800.48601.1580114.80000.1780

Notes: B1, speculum Barraquer odous with open blade; B2, speculum Liebermann forceps with open blade; B3, speculum Barraquer odous with closed blade; B4, speculum Lieberman odous with closed blade.

Abbreviations: AF, after pressure; ast., astigmatism; CR, cylindrical refraction; K1, steepest keratometric reading; K2, flattest keratometric reading; OPD, OPD-SCAN III; ORA, optiwave response analyzer; SE, spherical equivalent; SR, spherical refraction; WF, without pressure.

Table 3

Ranking of variables by order of the smallest mean absolute distances (only those whose equality test p-value has not been rejected)

SpeculumSR OPDCR OPDAxis of ast. refraction OPDSE refraction OPDValue of K1 OPDAxis of K1 OPDValue of K2 OPDAxis of K2 OPDValue of ast. OPDSR ORACR ORAAxis of ast. refraction ORASE refraction ORA
B1AF2451341
B1WF174551
B2AF15322
B2WF12442131
B3AF122721
B3WF22116
B4AF3338536
B4WF35361243

Notes: B1, speculum Barraquer odous with open blade; B2, speculum Liebermann forceps with open blade; B3, speculum Barraquer odous with closed blade; B4, speculum Lieberman odous with closed blade.

Abbreviations: AF, after pressure; ast., astigmatism; CR, cylindrical refraction; K1, steepest keratometric reading; K2, flattest keratometric reading; OPD, OPD-SCAN III; ORA, optiwave response analyzer; SE, spherical equivalent; SR, spherical refraction; WF, without pressure.

Table 4

Ranking of posts (weighted average: rankings sum × no of rejections)

SpeculumCumulative rankingRejectionsPointsFinal ranking
B1AF2061205
B1WF2371617
B2AF1381043
B2WF185901
B3AF1571054
B3WF128962
B4AF3161868
B4WF2751356

Notes: B1, speculum barraquer odous with open blade; B2, speculum Liebermann forceps with open blade; B3, speculum barraquer odous with closed blade; B4, speculum lieberman odous with closed blade.

Abbreviations: AF, after forcing; ast., astigmatism; CR, cylindrical refraction; ORA, optiwave response analyzer; SE, spherical equivalent; SR, spherical refraction; WF, without force.

The study was conducted in accordance with the principles of the Declaration of Helsinki and was approved by the institutional review board (IRB) of the Hospital Oftalmológico de Brasília with written informed consent provided by the patients.

Results

Comparing the spherical refraction in the OPD with and without blepharostat, B1 without pressure (WF), B2 after pressure (AF), B3AF, B3WF, B3AF, and B4AF were statistically significant (0.50 D of median±0.38 D of SD, p=0.0186; 0.50±0.41 D, p=0.0402; 1.25±0.57 D, p=0.007; 1.50±0.72 D, p=0.0138; 0.25±0.33 D, p=0.0367, respectively); the other analyses were not significant. In the cylindrical refraction from the OPD with and without blepharostat, only the blepharostats, B3AF and B3WF, presented statistical significance (2.50±0.94 D, p=0.0058; 1.25±0.70 D, p=0.0244, respectively). With respect to the axis of refraction in the OPD, only the B1WF, B2AF, and B4WF blepharostats presented statistical significance (82°±46.38°, p=0.0073; 29°±18.39°, p=0.0403; 38°±40.78°, p=0.0448, respectively). The SE presented statistical significance in the blepharostats such as B1WF, B2AF, B2WF, B3AF, and B4AF (0.50±0.40 D, p=0.03; 0.38±0.10 D, p=0.0009; 0.13±0.13 D, p=0.0184; 0.74±0.54 D, p=0.034; 1.00±0.58 D, p=0.0158, respectively). When we evaluated the corneal curvature with the OPD, we observed that the blepharostats, B1WF, B1AF, B2WF, B2AF, and B4WF, significantly altered the corneal axis (K1; 0.37± 0.32 D, p=0.048; 0.28±0.33 D, p=0.0476; 0.62±0.43 D, p=0.029; 0.97±0.39 D, p=0.0135; 0.54±0.55 D, p=0.0269, respectively). However, when we observed the K1 axis, no blepharostat presented statistically significant results. The most curved axis (K2) was statistically significant in the following: B1AF, B3AF, and B3WF (0.70±0.27 D, p=0.042; 1.53±0.52 D, p=0.0045; 0.59±0.51 D, p=0.0201, respectively). In the K2 axis only, the B2AF blepharostat presented a statistically significant result, 16°±7.96°, p=0.0155. With respect to the astigmatism of the OPD, only the B3AF and B3WF speculums had significant results (2.04±1.59 D, p=0.0181; 1.42±0.70 D, p=0.0149, respectively). When we compared the blepharostats in the spherical refraction in the ORA device, we obtained the following blepharotats with significance: B1AF, B1WF, B2AF, B3WF and B4AF (0.2±0.0942 D, p=0.0078; 0.52±0.3174 D, p=0.0393; 0.71±0.5633 D, p=0.0315; 1.18±0.3057 D, p=0.0016; 0.41±0.1837 D, p=0.0136, respectively). In the cylindrical refraction, we found the following blepharotats with significance: B1AF, B2WF, B3AF, B3WF, B4AF, and B4WF (0.57±0.2230 D, p=0.0095; 1.11±0.2520 D, p=0.0005; 0.96±0.2261 D, p=0.0011; 0.65±0.4235 D, p=0.0186; 0.92±0.5705 D, p=0.0113; 1.00±0.5527 D, p=0.0094, respectively). In the comparison of the ORA refraction axis, all B1AF, B1WF, B2AF, B2WF, B3AF, B3WF, B4AF, and B4WF were statistically significant (89°±11,4543°, p=0.0001; 90°±16.9263°, p=0.0003; 83°±7.8549°, p=0.00001; 119°±24.4131°, p=0.0003; 123°±23.8584°, p=0.0005; 106°±21.9704°, p=0.0007; 135°±27.3002°, p=0.0005; 112°±30.2605°, p=0.0011, respectively). As for SE in the ORA, B1AF, B1WF, B2AF, B2WF, B3WF, B4AF and B4WF presented statistical significance (0.15±0.2501 D, p=0.0451; 0.35±0.1976 D, p=0.0167; 0.35±0.1031 D, p=0.002; 0.19±0.1412 D, p=0.0147; 1.00±0.2406 D, p=0.0008; 0.57±0.3898 D, p=0.0388; 0.21±0.1094 D, p=0.022, respectively).

Discussion

This is the first study to compare the effect of blepharostats on the ORA aberrometric measurement; furthermore, this is an unpublished study and there are no other studies to compare with. As a comparison of the data collected from the OPD with speculum with the data of the OPD without blepharostat and with the ORA measurement data was performed, a correlative inference between the OPD groups with speculum and ORA with speculum regarding the statistical comparison was established; therefore, the blepharostat that might influence less on the aphakic reading of the ORA could be settled. In the present study, there was an observation that the SE of the OPD with the use of blepharostat compared to the OPD without blepharostat presented only 37.5% of results without statistical significance. Regarding the SE of the ORA with the use of speculums compared to the OPD without blepharostat, only 12.5% were not significant. Regarding the accuracy of the ORA axis with the use of blepharostats, all results presented statistical significance.

Conclusion

It is possible to infer that the comparative analysis of ORA in relation to the OPD without blepharostat was inferior to the analysis of the OPD with speculum. The open blade threaded blepharostat (Lieberman, Katena) was the most similar to the data capture of the OPD without speculum, when the patient does or does not force the eye to close. Thus, in the present study, we reached the conclusion that the most suitable for use in the aphakic and pseudophakic ORA capture is the open blade threaded blepharostat, Lieberman (Katena), probably due to the speculum design.
  8 in total

1.  New blepharostat for ocular surgery of anterior segment.

Authors:  J I BARRAQUER
Journal:  Ophthalmologica       Date:  1957-09       Impact factor: 3.250

2.  Cost-effectiveness of femtosecond laser-assisted cataract surgery versus phacoemulsification cataract surgery.

Authors:  Robin G Abell; Brendan J Vote
Journal:  Ophthalmology       Date:  2013-10-10       Impact factor: 12.079

Review 3.  Intraoperative wavefront aberrometry in cataract surgery.

Authors:  Houman D Hemmati; Daniel Gologorsky; Roberto Pineda
Journal:  Semin Ophthalmol       Date:  2012 Sep-Nov       Impact factor: 1.975

4.  Improvement in error propagation in the Shack-Hartmann-type zonal wavefront sensors.

Authors:  Biswajit Pathak; Bosanta R Boruah
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2017-12-01       Impact factor: 2.129

5.  Functional outcomes after bilateral implantation of apodized diffractive aspheric acrylic intraocular lenses with a +3.0 or +4.0 diopter addition power Randomized multicenter clinical study.

Authors:  W Andrew Maxwell; Robert J Cionni; Robert P Lehmann; Satish S Modi
Journal:  J Cataract Refract Surg       Date:  2009-12       Impact factor: 3.351

6.  Intraoperative refractive biometry for predicting intraocular lens power calculation after prior myopic refractive surgery.

Authors:  Tsontcho Ianchulev; Kenneth J Hoffer; Sonia H Yoo; David F Chang; Michael Breen; Thomas Padrick; Dan B Tran
Journal:  Ophthalmology       Date:  2013-10-30       Impact factor: 12.079

7.  An evaluation of the accuracy of the ORange (Gen II) by comparing it to the IOLMaster in the prediction of postoperative refraction.

Authors:  Ming Chen
Journal:  Clin Ophthalmol       Date:  2012-03-13

8.  Comparison of visual outcomes after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of an extended depth of focus intraocular lens with a diffractive bifocal intraocular lens.

Authors:  André Lins de Medeiros; André Gustavo de Araújo Rolim; Antonio Francisco Pimenta Motta; Bruna Vieira Ventura; César Vilar; Mário Augusto Pereira Dias Chaves; Pedro Carlos Carricondo; Wilson Takashi Hida
Journal:  Clin Ophthalmol       Date:  2017-10-26
  8 in total
  1 in total

1.  Use of Simultaneous Bilateral Cataract Surgery (SBCS) to Optimize Parameters Affecting the Subjective Perception of the Procedure.

Authors:  P Studený; J Vránová; L Nováček
Journal:  J Ophthalmol       Date:  2021-06-11       Impact factor: 1.909

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.