Literature DB >> 31286454

Dose perturbation by metallic biliary stent in external beam radiotherapy of pancreato-biliary cancers.

Ho Lee1, Jeongmin Yoon2, Kwangwoo Park2, Chai Hong Rim2, Moon Jae Chung3, Jinsil Seong4.   

Abstract

This study aims to investigate dose perturbations caused by a metallic biliary stent (MBS) in patients undergoing external beam radiotherapy for cancers in the pancreato-biliary region. Four MBSs with nitinol mesh were examined in the EasyCube® phantom including a custom stent holder fabricated by a 3D printer. For experimental models, three-dimensional conformal radiotherapy plans using a single anterior-posterior (AP) and four-field box (4FB) as well as volumetric modulated arc therapy (VMAT) plan were prepared to deliver the photon beam of 8 Gy to the stent holder. EBT3 film was used to measure dose distributions at four sides surrounding MBS. All MBSs in the AP beam demonstrated mean dose enhancements of 2.3-8.2% at the proximal, left, and right sides. Maximum dose enhancements of 12.3-19.5% appeared at regions surrounding the radiopaque markers. At the location distal to the source, there were mean dose reductions of - 3.6 to - 10.9% and minimum doses of - 11.1 to - 9.5%. The mean and maximum doses with the 4FB plan were in the ranges of - 0.1 to 3.6% and 6.7-14.9%, respectively. The VMAT produced mean doses of - 0.9 to 4.8% and maximum doses of 6.0-15.3%. Dose perturbations were observed with maximum and minimum spots near the stent surface. The use of multiple beams including parallel-opposed pairs reduced dose perturbations caused by the nitinol and radiopaque components within the stent. Special attention is required for patients in whom the radiopaque markers are closely located near critical structures or the target volume.

Entities:  

Keywords:  3D printer; Cancers in the pancreato-biliary region; Dose perturbation; External beam radiation; Metallic biliary stent

Year:  2019        PMID: 31286454     DOI: 10.1007/s13246-019-00774-1

Source DB:  PubMed          Journal:  Australas Phys Eng Sci Med        ISSN: 0158-9938            Impact factor:   1.430


  3 in total

1.  Safety of biliary stent placement followed by definitive chemoradiotherapy in patients with pancreatic cancer with bile duct obstruction.

Authors:  Sara Hayakawa; Kei Ito; Jin Hayakawa; Keiko Nemoto Murofushi; Katsuyuki Karasawa
Journal:  J Gastrointest Oncol       Date:  2021-10

2.  Assessment of dose perturbations for metal stent in photon and proton radiotherapy plans for hepatocellular carcinoma.

Authors:  Boram Lee; Sungkoo Cho; Hee Chul Park; Sang-Won Kang; Jae-Sung Kim; Jin-Beom Chung
Journal:  Radiat Oncol       Date:  2022-07-16       Impact factor: 4.309

3.  Patient-Specific Quality Assurance Using a 3D-Printed Chest Phantom for Intraoperative Radiotherapy in Breast Cancer.

Authors:  Yeonho Choi; Ik Jae Lee; Kwangwoo Park; Kyung Ran Park; Yeona Cho; Jun Won Kim; Ho Lee
Journal:  Front Oncol       Date:  2021-03-15       Impact factor: 6.244

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.