Literature DB >> 31283640

Use of Unsintered Hydroxyapatite and Poly-L-lactic Acid Composite Sheets for Management of Orbital Wall Fracture.

Shinya Tsumiyama1, Go Umeda, Kunitoshi Ninomiya, Takeshi Miyawaki.   

Abstract

Although unsintered hydroxyapatite and poly-L-lactic acid (u-HA/PLLA) composite sheets have various applications, such as in craniomaxillofacial fractures, orthognathic surgery, and orthopedic surgery, and have been proven to be safe and effective, no studies have reported the use of u-HA/PLLA composite sheets for orbital wall reconstruction with long-term follow-up. This study reports our preliminary results using the u-HA/PLLA composite sheet for orbital wall fractures. The SuperFIXSORB MX sheet (u-HA/PLLA composite sheet; Takiron, Tokyo, Japan), with size of 30 × 50 mm and thickness of 0.5 mm, was used in all cases of hard reconstruction of the orbital bone defect. Seventy-two patients with acute orbital wall fractures (within 2 weeks after sustaining the injury) treated at the Jikei University between January 2014 and August 2016 were included. The authors evaluated the postoperative complications and the operability of the material. The authors did not observe any postoperative complications, such as infection, postoperative diplopia, or enophthalmos, due to the use of the u-HA/PLLA composite sheet. In pure orbital fractures (orbital fractures only), the mean (±standard deviation) operation time was significantly longer with combined inferior and medial wall fractures (201.1 ± 36.6 minutes; n = 11) than with inferior wall or medial wall fractures only (135.0 ± 54.4 minutes; n = 51) (Mann-Whitney U test, P < 0.001). The U-HA/PLLA composite sheet is safe and can be used for orbital wall fracture reconstruction. Further long-term functional and aesthetic assessments for infection, ocular movement disorder, enophthalmos, and any other complication are necessary.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 31283640     DOI: 10.1097/SCS.0000000000005734

Source DB:  PubMed          Journal:  J Craniofac Surg        ISSN: 1049-2275            Impact factor:   1.046


  3 in total

Review 1.  A Narrative Review of u-HA/PLLA, a Bioactive Resorbable Reconstruction Material: Applications in Oral and Maxillofacial Surgery.

Authors:  Huy Xuan Ngo; Yunpeng Bai; Jingjing Sha; Shinji Ishizuka; Erina Toda; Rie Osako; Akira Kato; Reon Morioka; Mrunalini Ramanathan; Hiroto Tatsumi; Tatsuo Okui; Takahiro Kanno
Journal:  Materials (Basel)       Date:  2021-12-26       Impact factor: 3.623

2.  Is Surgery Needed for Diplopia after Blowout Fractures? A Clarified Algorithm to Assist Decision-making.

Authors:  Cen-Hung Lin; Su-Shin Lee; I Wen Lin; Wan-Ju Su
Journal:  Plast Reconstr Surg Glob Open       Date:  2022-05-09

3.  Bioactive Regeneration Potential of the Newly Developed Uncalcined/Unsintered Hydroxyapatite and Poly-l-Lactide-Co-Glycolide Biomaterial in Maxillofacial Reconstructive Surgery: An In Vivo Preliminary Study.

Authors:  Shinji Ishizuka; Quang Ngoc Dong; Huy Xuan Ngo; Yunpeng Bai; Jingjing Sha; Erina Toda; Tatsuo Okui; Takahiro Kanno
Journal:  Materials (Basel)       Date:  2021-05-10       Impact factor: 3.623

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.