Literature DB >> 31283510

A 122 fps, 1 MHz Bandwidth Multi-Frequency Wearable EIT Belt Featuring Novel Active Electrode Architecture for Neonatal Thorax Vital Sign Monitoring.

Yu Wu, Dai Jiang, Andy Bardill, Richard Bayford, Andreas Demosthenous.   

Abstract

A highly integrated, wearable electrical impedance tomography (EIT) belt for neonatal thorax vital multiple sign monitoring is presented. The belt has 16 active electrodes. Each electrode has an application-specific integrated circuit (ASIC) connected to it. The ASIC contains a fully differential current driver, a high-performance instrumentation amplifier, a digital controller, and multiplexors. The belt features a new active electrode architecture that allows programmable flexible electrode current drive and voltage sense patterns under simple digital control. It provides intimate connections to the electrodes for the current drive and to the IA for direct differential voltage measurement, providing superior common-mode rejection ratio. The ASIC was designed in a CMOS 0.35-μm high-voltage technology. The high-specification EIT belt has an image frame rate of 122 fps, a wide operating bandwidth of 1 MHz, and multi-frequency operation. It measures impedance with 98% accuracy and has less than 0.5 Ω and 1° variation across all possible channels. The image results confirmed the advantage of the new active electrode architecture and the benefit of wideband, multi-frequency EIT operation. The system successfully captured high-quality lung-respiration EIT images, breathing cycle, and heart rate. It can also provide boundary-shape information by using an array of MEMS sensors interfaced to the ASICs.

Entities:  

Mesh:

Year:  2019        PMID: 31283510     DOI: 10.1109/TBCAS.2019.2925713

Source DB:  PubMed          Journal:  IEEE Trans Biomed Circuits Syst        ISSN: 1932-4545            Impact factor:   3.833


  3 in total

1.  FPGA-Based Processor for Continual Capacitive-Coupling Impedance Spectroscopy and Circuit Parameter Estimation.

Authors:  Akihiko Tsukahara; Tomiharu Yamaguchi; Yuho Tanaka; Akinori Ueno
Journal:  Sensors (Basel)       Date:  2022-06-10       Impact factor: 3.847

2.  System introduction and evaluation of the first Chinese chest EIT device for ICU applications.

Authors:  Shuo-Yao Qu; Meng Dai; Shuo Wu; Zhi-Rang Lv; Xin-Yu Ti; Feng Fu
Journal:  Sci Rep       Date:  2021-09-29       Impact factor: 4.379

3.  A Point-Matching Method of Moment with Sparse Bayesian Learning Applied and Evaluated in Dynamic Lung Electrical Impedance Tomography.

Authors:  Christos Dimas; Vassilis Alimisis; Nikolaos Uzunoglu; Paul P Sotiriadis
Journal:  Bioengineering (Basel)       Date:  2021-11-25
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.