Literature DB >> 3128132

The reason for cardiac output reduction after aortic cross-clamping.

S Gelman1, H McDowell, P D Varner, J Pearson, J Ebert, G Graybar, J Proctor.   

Abstract

The hypothesis that a decrease in cardiac output during infrarenal aortic cross-clamping is related to a decrease in oxygen consumption in the perfused tissues (cross-clamp-adapted oxygen consumption) rather than to deterioration of myocardial performance has been tested. Twenty-two patients undergoing excision of an aortic abdominal aneurysm were randomly divided into two groups of equal number. During aortic cross-clamping, Group 1 patients received nitroglycerin infusion, 1 to 2 micrograms.kg-1.min-1, whereas Group 2 patients did not receive a nitroglycerin infusion. During aortic cross-clamping, cross-clamp-adapted body oxygen consumption decreased equally in both groups by 40 to 42 percent of baseline values, whereas cardiac output decreased by 17 percent in Group 2 but did not change significantly in Group 1. Mixed venous oxygen content increased significantly after induction of anesthesia and prior to aortic cross-clamping in both groups. During cross-clamping, the values of mixed venous oxygen content remained increased in Group 2 and increased further in Group 1. The data support our hypothesis since a decrease in cardiac output was not associated with an increase in filling pressures during aortic cross-clamping, but was instead associated with an increase in mixed venous oxygen content and a decrease in the arteriovenous oxygen content difference. Nitroglycerin infusion was associated with a further increase in mixed venous oxygen content during aortic cross-clamping and a decrease in the arteriovenous oxygen content difference, without a concomitant increase in oxygen utilization.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3128132     DOI: 10.1016/s0002-9610(88)80413-6

Source DB:  PubMed          Journal:  Am J Surg        ISSN: 0002-9610            Impact factor:   2.565


  2 in total

Review 1.  Anaesthesia for abdominal aortic surgery--a review (Part II).

Authors:  A J Cunningham
Journal:  Can J Anaesth       Date:  1989-09       Impact factor: 5.063

2.  Extending resuscitative endovascular balloon occlusion of the aorta: Endovascular variable aortic control in a lethal model of hemorrhagic shock.

Authors:  Timothy Keith Williams; Lucas P Neff; Michael Austin Johnson; Sarah-Ashley Ferencz; Anders J Davidson; Rachel M Russo; Todd E Rasmussen
Journal:  J Trauma Acute Care Surg       Date:  2016-08       Impact factor: 3.313

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.