Literature DB >> 31279405

Everolimus-Eluting Versus Biolimus-Eluting Coronary Stent Implantation in Patients With and Without Diabetes Mellitus.

Christine Gyldenkerne1, Kevin K W Olesen2, Lisette O Jensen3, Anders Junker3, Karsten T Veien3, Christian J Terkelsen1, Steen D Kristensen1, Troels Thim1, Svend E Jensen4, Bent Raungaard4, Jens Aaroe4, Johnny Kahlert5, Anton B Villadsen4, Hans Erik Bøtker1, Evald H Christiansen1, Michael Maeng6.   

Abstract

Diabetes mellitus is associated with a higher risk of target lesion revascularization after percutaneous coronary intervention. We compared clinical outcomes in patients with and without diabetes mellitus, treated with everolimus-eluting stents (EES; Synergy; Boston Scientific, Marlborough, Massachusetts) or biolimus-eluting stents (BES; BioMatrix NeoFlex; Biosensors Interventional Technologies Pte Ltd., Singapore). In total, 2,764 patients were randomized to stent implantation with EES (n = 1,385, diabetes: n = 250) or the BES (n = 1,379, diabetes: n = 262), stratified by gender and diabetes. The primary end point, target lesion failure (TLF), was a composite of cardiac death, target-lesion myocardial infarction, or target lesion revascularization at 12 months. Secondary end points included individual components of TLF, all-cause death, and stent thrombosis. TLF was 2.1% lower in the EES versus the BES groups in patients with diabetes (3.6% vs 5.7%; rate ratios 0.61, 95% confidence interval [CI] 0.27 to 1.41) and similar in patients without diabetes (4.1% vs 4.0%; rate ratios 0.99, 95% CI 0.66 to 1.51). In patients with diabetes, the point estimates of the individual components of TLF also favored the EES but CIs were wide. No interaction between stent type and presence of diabetes was found. The current subgroup analysis found that a thin-strut EES as compared with a thicker strut BES had a numerically lower TLF rate in patients with diabetes, but the subgroup analysis was underpowered for definite conclusions.
Copyright © 2019. Published by Elsevier Inc.

Entities:  

Year:  2019        PMID: 31279405     DOI: 10.1016/j.amjcard.2019.05.060

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  2 in total

Review 1.  Current Use and Trends in Unprotected Left Main Coronary Artery Percutaneous Intervention.

Authors:  Harsha S Nagarajarao; Chandra P Ojha; Venkatachalam Mulukutla; Ahmed Ibrahim; Adriana C Mares; Timir K Paul
Journal:  Curr Cardiol Rep       Date:  2020-02-08       Impact factor: 2.931

2.  Impact of diabetes on clinical outcomes after revascularization with the dual therapy CD34 antibody-covered sirolimus-eluting Combo stent and the sirolimus-eluting Orsiro stent.

Authors:  Lars Jakobsen; Evald H Christiansen; Phillip Freeman; Johnny Kahlert; Karsten Veien; Michael Maeng; Bent Raungaard; Julia Ellert; Steen D Kristensen; Martin K Christensen; Christian J Terkelsen; Troels Thim; Ashkan Eftekhari; Rebekka V Jensen; Nicolaj B Støttrup; Anders Junker; Henrik S Hansen; Lisette O Jensen
Journal:  Catheter Cardiovasc Interv       Date:  2022-04-06       Impact factor: 2.585

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.