| Literature DB >> 31278460 |
Dagmar Schaffler-Schaden1, Theresa Birsak2, Ramona Zintl3, Barbara Lorber4, Gottfried Schaffler2.
Abstract
PURPOSE: The objective of this study was to determine the incidence of needle track seeding after ultrasound-guided percutaneous biopsy of indeterminate liver lesions with a coaxial biopsy system without any other additional intervention or ablation therapy.Entities:
Keywords: Coaxial biopsy; Liver biopsy; Needle tract seeding; Ultrasound-guided biopsy
Mesh:
Year: 2020 PMID: 31278460 PMCID: PMC7455584 DOI: 10.1007/s00261-019-02120-1
Source DB: PubMed Journal: Abdom Radiol (NY)
Fig. 1Biopsy with coaxial technique in a 77-year-old female patient with multifocal lesions
Demographic data of patients and types of lesions
| Characteristics | Data |
|---|---|
| Sex (m) | 67 (51%) |
| Age | |
| Range | 31–91 |
| Median | 69 |
| Mean ± SD | 68.1 ± 10.8 |
| BMI (kg/m2) ( | |
| < 18.5 | 5 (4%) |
| 18.5–24.9 | 44 (38%) |
| ≥ 25 | 67 (58%) |
| Follow-up (days) | |
| Range | 31-3437 |
| Median | 315 |
| Mean ± SD | 648 ± 784 |
| No. of punches ( | |
| 1 | 37 (28%) |
| 2 | 61 (47%) |
| 3 | 27 (21%) |
| 4 | 5 (4%) |
| Pain | 24 (18%) |
| Bleeding | 6 (5%) |
| Primary (HCC + CC) | |
| Metastatic | |
| Mean size overall ( | 2.1 cm |
| Multifocal | 80/127 |
| Diffuse | 13/127 |
Risk ratio of the main risk factors
| Risk Factor | RR pain | RR bleeding | |
|---|---|---|---|
| Female | 64 (49) | 1.24 | 1.05 |
| Metastatic disease | 87 (66) | 1.23 | 1.01 |
| Multifocal findings ( | 80 (63) | 1.53 | 1.70 |
| Lesion: ø ≥ 2.5 cm ( | 76 (63) | 1.01 | 2.32 |